| contributor author | P. C. Richards | |
| date accessioned | 2017-05-08T23:03:17Z | |
| date available | 2017-05-08T23:03:17Z | |
| date copyright | November, 1977 | |
| date issued | 1977 | |
| identifier issn | 1087-1357 | |
| identifier other | JMSEFK-27666#809_1.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/90136 | |
| description abstract | Experiments have shown that the Jenike bunker outlet design method is accurate with respect to both the flow pattern (mass flow or funnel flow) and the minimum outlet required. Initial measurements of wall pressures in a 0.6-m-dia mass flow bunker were used to select a suitable measuring technique for use in larger scale equipment, which is also described. | |
| publisher | The American Society of Mechanical Engineers (ASME) | |
| title | Bunker Design—Part 1: Bunker Outlet Design and Initial Measurements of Wall Pressures | |
| type | Journal Paper | |
| journal volume | 99 | |
| journal issue | 4 | |
| journal title | Journal of Manufacturing Science and Engineering | |
| identifier doi | 10.1115/1.3439354 | |
| journal fristpage | 809 | |
| journal lastpage | 813 | |
| identifier eissn | 1528-8935 | |
| keywords | Measurement | |
| keywords | Design | |
| keywords | Flow (Dynamics) AND Design methodology | |
| tree | Journal of Manufacturing Science and Engineering:;1977:;volume( 099 ):;issue: 004 | |
| contenttype | Fulltext | |