YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASCE
    • Journal of Composites for Construction
    • View Item
    •   YE&T Library
    • ASCE
    • Journal of Composites for Construction
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Behavior of GFRP-RC Interior Slab-Column Connections with Shear Studs and High-Moment Transfer

    Source: Journal of Composites for Construction:;2016:;Volume ( 020 ):;issue: 004
    Author:
    Ahmed Gouda
    ,
    Ehab El-Salakawy
    DOI: 10.1061/(ASCE)CC.1943-5614.0000663
    Publisher: American Society of Civil Engineers
    Abstract: Six full-scale reinforced-concrete (RC) interior slab-column connections of glass fiber–reinforced polymer (GFRP) were constructed and tested to failure. The specimen consisted of a square slab with a 2,800-mm side length and a 200-mm thickness in addition to a 300-mm-square column stub extended for 1,000 mm above and below the slab. The test specimens were subjected to vertical shear forces and unbalanced moments. The test variables included the moment-to-shear ratio, GFRP double-headed shear studs ratio, and the type of GFRP bar surface texture (ribbed or sand-coated). The test results revealed that increasing the moment-to-shear ratio reduced the vertical shear capacity and increased the deflections and the strains at failure. Moreover, the presence of the GFRP shear studs enhanced the slab capacity but was not able to change the punching shear mode of failure. Furthermore, the used two types of GFRP bars showed comparable behavior. The results were compared with the predictions of the available fiber-reinforced polymer (FRP) design provisions such as those from Canada, the United States, and Japan. Finally, a new method is proposed to predict the punching shear capacity for the slabs with FRP shear studs.
    • Download: (11.18Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Behavior of GFRP-RC Interior Slab-Column Connections with Shear Studs and High-Moment Transfer

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/82415
    Collections
    • Journal of Composites for Construction

    Show full item record

    contributor authorAhmed Gouda
    contributor authorEhab El-Salakawy
    date accessioned2017-05-08T22:32:55Z
    date available2017-05-08T22:32:55Z
    date copyrightAugust 2016
    date issued2016
    identifier other49202736.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/82415
    description abstractSix full-scale reinforced-concrete (RC) interior slab-column connections of glass fiber–reinforced polymer (GFRP) were constructed and tested to failure. The specimen consisted of a square slab with a 2,800-mm side length and a 200-mm thickness in addition to a 300-mm-square column stub extended for 1,000 mm above and below the slab. The test specimens were subjected to vertical shear forces and unbalanced moments. The test variables included the moment-to-shear ratio, GFRP double-headed shear studs ratio, and the type of GFRP bar surface texture (ribbed or sand-coated). The test results revealed that increasing the moment-to-shear ratio reduced the vertical shear capacity and increased the deflections and the strains at failure. Moreover, the presence of the GFRP shear studs enhanced the slab capacity but was not able to change the punching shear mode of failure. Furthermore, the used two types of GFRP bars showed comparable behavior. The results were compared with the predictions of the available fiber-reinforced polymer (FRP) design provisions such as those from Canada, the United States, and Japan. Finally, a new method is proposed to predict the punching shear capacity for the slabs with FRP shear studs.
    publisherAmerican Society of Civil Engineers
    titleBehavior of GFRP-RC Interior Slab-Column Connections with Shear Studs and High-Moment Transfer
    typeJournal Paper
    journal volume20
    journal issue4
    journal titleJournal of Composites for Construction
    identifier doi10.1061/(ASCE)CC.1943-5614.0000663
    treeJournal of Composites for Construction:;2016:;Volume ( 020 ):;issue: 004
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian