    Combined Loading Behavior of Basalt FRP–Reinforced Precast Concrete Insulated Partially-Composite Walls

    Source: Journal of Composites for Construction:;2016:;Volume ( 020 ):;issue: 003
    Author:
    Douglas Tomlinson
    ,
    Amir Fam
    DOI: 10.1061/(ASCE)CC.1943-5614.0000611
    Publisher: American Society of Civil Engineers
    Abstract: The axial and flexure combined loading performance of a slender partially-composite concrete insulated wall design constructed using basalt fiber-reinforced polymer (BFRP) shear connectors and longitudinal BFRP reinforcement is investigated. The load-bearing wall panel sections, 600 mm wide and 2,700 mm long, were first subjected to axial loads ranging from 0 to 900 kN applied to the structural wythe only. The panels were then loaded to failure in four-point bending to develop the axial load-bending moment interaction diagram of the partially-composite system, which was compared to theoretical fully-composite and noncomposite curves. As axial load increased, failure under transverse loading changed from shear-compression of the structural wythe to diagonal splitting of insulation foam and rupture of BFRP connectors, then to crushing of the structural wythe. Composite action by the strength criterion reduced from 47 to 3% as axial load increased from 150 to 900 kN; while that by the stiffness criterion was much lower, 8–2.5%. Relative to a similar steel-reinforced wall panel with the same reinforcement ratio, the tested walls were 60–89% the strength; and the percentage increased with axial load. A method is introduced to estimate the effective centroid of the partially-composite wall in order to calculate the moment from the eccentric axial load applied to this load-bearing system.
    • Download: (37.37Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Combined Loading Behavior of Basalt FRP–Reinforced Precast Concrete Insulated Partially-Composite Walls

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/81138
    Collections
    • Journal of Composites for Construction

    Show full item record

    contributor authorDouglas Tomlinson
    contributor authorAmir Fam
    date accessioned2017-05-08T22:28:15Z
    date available2017-05-08T22:28:15Z
    date copyrightJune 2016
    date issued2016
    identifier other45922396.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/81138
    description abstractThe axial and flexure combined loading performance of a slender partially-composite concrete insulated wall design constructed using basalt fiber-reinforced polymer (BFRP) shear connectors and longitudinal BFRP reinforcement is investigated. The load-bearing wall panel sections, 600 mm wide and 2,700 mm long, were first subjected to axial loads ranging from 0 to 900 kN applied to the structural wythe only. The panels were then loaded to failure in four-point bending to develop the axial load-bending moment interaction diagram of the partially-composite system, which was compared to theoretical fully-composite and noncomposite curves. As axial load increased, failure under transverse loading changed from shear-compression of the structural wythe to diagonal splitting of insulation foam and rupture of BFRP connectors, then to crushing of the structural wythe. Composite action by the strength criterion reduced from 47 to 3% as axial load increased from 150 to 900 kN; while that by the stiffness criterion was much lower, 8–2.5%. Relative to a similar steel-reinforced wall panel with the same reinforcement ratio, the tested walls were 60–89% the strength; and the percentage increased with axial load. A method is introduced to estimate the effective centroid of the partially-composite wall in order to calculate the moment from the eccentric axial load applied to this load-bearing system.
    publisherAmerican Society of Civil Engineers
    titleCombined Loading Behavior of Basalt FRP–Reinforced Precast Concrete Insulated Partially-Composite Walls
    typeJournal Paper
    journal volume20
    journal issue3
    journal titleJournal of Composites for Construction
    identifier doi10.1061/(ASCE)CC.1943-5614.0000611
    treeJournal of Composites for Construction:;2016:;Volume ( 020 ):;issue: 003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian