| contributor author | Alok Goyal | |
| contributor author | Anil K. Chopra | |
| date accessioned | 2017-05-08T22:25:43Z | |
| date available | 2017-05-08T22:25:43Z | |
| date copyright | July 1989 | |
| date issued | 1989 | |
| identifier other | %28asce%290733-9399%281989%29115%3A7%281413%29.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/80475 | |
| description abstract | A simplified analysis procedure is developed to determine the maximum earthquake forces in intake‐outlet towers directly from the design earthquake spectrum without the need for a response history analysis. All the significant effects of tower‐water interaction and tower‐foundation‐soil, interaction are included in the analysis. It is demonstrated that the hydrodynamic effects can be approximated by added mass functions for outside and inside water. An equivalent SDF system is developed to consider approximately the effects of tower‐foundation‐soil interaction in the fundamental mode response of towers. | |
| publisher | American Society of Civil Engineers | |
| title | Earthquake Response Spectrum Analysis of Intake‐Outlet Towers | |
| type | Journal Paper | |
| journal volume | 115 | |
| journal issue | 7 | |
| journal title | Journal of Engineering Mechanics | |
| identifier doi | 10.1061/(ASCE)0733-9399(1989)115:7(1413) | |
| tree | Journal of Engineering Mechanics:;1989:;Volume ( 115 ):;issue: 007 | |
| contenttype | Fulltext | |