| description abstract | This paper presents the results of large-deflection resistance testing of partially grouted single-wythe and multiwythe insulated masonry walls. Three design sections were evaluated under uniform pressure in a vacuum chamber test, as follows: (1) 150-mm (6-in.) standard block masonry wall reinforced with 10-mm (No. 3) rebar at 80-cm (32-in.) maximum spacing; (2) 200-mm (8-in.) standard block masonry wall reinforced with 13-mm (No. 4) rebar at 120-cm (48-in.) maximum spacing; and (3) a cavity wall consisting of 200-mm (8-in.) standard reinforced concrete masonry unit (CMU) wythe, a 100-mm (4-in.) clay facing brick veneer with 50-mm (2-in.)-thick extruded polystyrene rigid board insulation, and a 25-mm (1-in.) air gap between the structural wythe and the veneer. Each test panel was | |
| publisher | American Society of Civil Engineers | |
| title | Performance of Partially Grouted, Minimally Reinforced CMU Cavity Walls against Blast Demands. I: Large Deflection Static Resistance under Uniform Pressure | |
| type | Journal Paper | |
| journal volume | 29 | |
| journal issue | 4 | |
| journal title | Journal of Performance of Constructed Facilities | |
| identifier doi | 10.1061/(ASCE)CF.1943-5509.0000508 | |
| tree | Journal of Performance of Constructed Facilities:;2015:;Volume ( 029 ):;issue: 004 | |
| contenttype | Fulltext | |