    CLT–Steel Hybrid System: Ductility and Overstrength Values Based on Static Pushover Analysis

    Source: Journal of Performance of Constructed Facilities:;2014:;Volume ( 028 ):;issue: 006
    Author:
    C. Dickof
    ,
    S. F. Stiemer
    ,
    M. A. Bezabeh
    ,
    S. Tesfamariam
    DOI: 10.1061/(ASCE)CF.1943-5509.0000614
    Publisher: American Society of Civil Engineers
    Abstract: A timber-steel hybrid system, where cross-laminated timber (CLT) shear panels are used as infill in steel moment resisting frames, is analytically investigated. The proposed hybrid system combines ductile behavior of steel moment frame with lighter and stiffer CLT panels. Initial parametric study is carried out with a single-bay-single-story model using pushover analysis to investigate effect of CLT panel thickness, crushing strength, and confinement gap. Results showed that the parameters studied have a significant influence on system’s ultimate strength, ultimate drift capacity, and post-peak behavior. Subsequently, parametric studies are carried out for three-bay hybrid buildings with three-, six-, and nine-story hybrid buildings for varying panel configuration (a given gap, panel thickness, and crushing strength) values. The parameters varied and are design ductility level (limited ductility and ductile) and infill pattern. A monotonic pushover analysis was performed to develop a preliminary ductility and overstrength values based on both steel yield of frame and panel crushing force in the links. Overall, the results suggest that addition of infill bays is less beneficial in ductile moment frames; CLT infill panels are better suited to lower ductility systems. Ultimately, a ductility factor of 2.5 is recommended for the infilled frame system, and an overstrength factor of 1.25 appears to be warranted.
    • Download: (3.144Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      CLT–Steel Hybrid System: Ductility and Overstrength Values Based on Static Pushover Analysis

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/72924
    Collections
    • Journal of Performance of Constructed Facilities

    Show full item record

    contributor authorC. Dickof
    contributor authorS. F. Stiemer
    contributor authorM. A. Bezabeh
    contributor authorS. Tesfamariam
    date accessioned2017-05-08T22:10:48Z
    date available2017-05-08T22:10:48Z
    date copyrightDecember 2014
    date issued2014
    identifier other37302388.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/72924
    description abstractA timber-steel hybrid system, where cross-laminated timber (CLT) shear panels are used as infill in steel moment resisting frames, is analytically investigated. The proposed hybrid system combines ductile behavior of steel moment frame with lighter and stiffer CLT panels. Initial parametric study is carried out with a single-bay-single-story model using pushover analysis to investigate effect of CLT panel thickness, crushing strength, and confinement gap. Results showed that the parameters studied have a significant influence on system’s ultimate strength, ultimate drift capacity, and post-peak behavior. Subsequently, parametric studies are carried out for three-bay hybrid buildings with three-, six-, and nine-story hybrid buildings for varying panel configuration (a given gap, panel thickness, and crushing strength) values. The parameters varied and are design ductility level (limited ductility and ductile) and infill pattern. A monotonic pushover analysis was performed to develop a preliminary ductility and overstrength values based on both steel yield of frame and panel crushing force in the links. Overall, the results suggest that addition of infill bays is less beneficial in ductile moment frames; CLT infill panels are better suited to lower ductility systems. Ultimately, a ductility factor of 2.5 is recommended for the infilled frame system, and an overstrength factor of 1.25 appears to be warranted.
    publisherAmerican Society of Civil Engineers
    titleCLT–Steel Hybrid System: Ductility and Overstrength Values Based on Static Pushover Analysis
    typeJournal Paper
    journal volume28
    journal issue6
    journal titleJournal of Performance of Constructed Facilities
    identifier doi10.1061/(ASCE)CF.1943-5509.0000614
    treeJournal of Performance of Constructed Facilities:;2014:;Volume ( 028 ):;issue: 006
    contenttypeFulltext