contributor author | Mengkai Li | |
contributor author | Zhimin Qiang | |
contributor author | James R. Bolton | |
contributor author | Wentao Li | |
contributor author | Chen Wang | |
date accessioned | 2017-05-08T22:10:24Z | |
date available | 2017-05-08T22:10:24Z | |
date copyright | April 2015 | |
date issued | 2015 | |
identifier other | 37143086.pdf | |
identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/72811 | |
description abstract | Based on previously developed monitoring system comprising three microfluorescent silica detectors, this paper proposed an improved real-time fluence monitoring method for running ultraviolet (UV) reactors. Adoption of this new method would significantly decrease the number of biodosimetry tests while increase the monitoring accuracy. The method constants were first determined by biodosimetry; thereafter, a long-term (about 16 months) experiment was conducted to evaluate the continuous performance of the proposed method under simulated practical conditions. The results indicate that the daily average fluence dropped gradually from 248 to | |
publisher | American Society of Civil Engineers | |
title | Improved Method for Real-Time Fluence Monitoring in UV Reactors | |
type | Journal Paper | |
journal volume | 141 | |
journal issue | 4 | |
journal title | Journal of Environmental Engineering | |
identifier doi | 10.1061/(ASCE)EE.1943-7870.0000909 | |
tree | Journal of Environmental Engineering:;2015:;Volume ( 141 ):;issue: 004 | |
contenttype | Fulltext | |