    Interlaminar Shear Stress and Structure of Continuously Reinforced Concrete Composite Asphalt Pavements

    Source: Journal of Highway and Transportation Research and Development (English Edition):;2013:;Volume ( 007 ):;issue: 004
    Author:
    Li Sheng
    ,
    Li Yu-zhi
    ,
    Liu Zhao-hui
    ,
    Sun Zhi-lin
    DOI: 10.1061/JHTRCQ.0000341
    Publisher: American Society of Civil Engineers
    Abstract: This study calculated and analyzed the critical load position and influencing factors of interlaminar shear stress, with focus on the characteristics of and existing studies on continuously reinforced concrete and asphalt concrete (CRC + AC) composite pavement structure. The calculation and analysis were conducted using heat transfer theory, mechanics theory, and finite element method. Interlaminar structure and materials, as well as technology for CRC layer surface treatment, were investigated through indoor experiments and engineering application examples on the basis of interlaminar shear stress. Results show the following: (1) Longitudinal and lateral slips occur in CRC + AC structure because of weak interlaminar shear strength. (2) Interlaminar maximum shear stress decreases as the thickness and modulus of the AC layer increase, with the decrease trend being more obvious with increasing thickness of the AC layer. This trend is also observed along with the minimal effect of the thickness of the CRC layer on interlaminar maximum shear stress. As indicated by the analysis and calculations, combined with the measurements and construction experience of test road, the recommended thickness for AC layer is no less than 6 cm. It is recommended the spraying-type structure should use to treat the interlayer of CRC + AC structure, SBS modified asphalt use as spraying asphalt, and the baring technique use to treat the surface of CRC layer. These results can serve as important reference for the rational design of rigid-flexible composite asphalt pavements.
    • Download: (513.9Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Interlaminar Shear Stress and Structure of Continuously Reinforced Concrete Composite Asphalt Pavements

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/71773
    Collections
    • Journal of Highway and Transportation Research and Development (English Edition)

    Show full item record

    contributor authorLi Sheng
    contributor authorLi Yu-zhi
    contributor authorLiu Zhao-hui
    contributor authorSun Zhi-lin
    date accessioned2017-05-08T22:07:23Z
    date available2017-05-08T22:07:23Z
    date copyrightDecember 2013
    date issued2013
    identifier other29763207.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/71773
    description abstractThis study calculated and analyzed the critical load position and influencing factors of interlaminar shear stress, with focus on the characteristics of and existing studies on continuously reinforced concrete and asphalt concrete (CRC + AC) composite pavement structure. The calculation and analysis were conducted using heat transfer theory, mechanics theory, and finite element method. Interlaminar structure and materials, as well as technology for CRC layer surface treatment, were investigated through indoor experiments and engineering application examples on the basis of interlaminar shear stress. Results show the following: (1) Longitudinal and lateral slips occur in CRC + AC structure because of weak interlaminar shear strength. (2) Interlaminar maximum shear stress decreases as the thickness and modulus of the AC layer increase, with the decrease trend being more obvious with increasing thickness of the AC layer. This trend is also observed along with the minimal effect of the thickness of the CRC layer on interlaminar maximum shear stress. As indicated by the analysis and calculations, combined with the measurements and construction experience of test road, the recommended thickness for AC layer is no less than 6 cm. It is recommended the spraying-type structure should use to treat the interlayer of CRC + AC structure, SBS modified asphalt use as spraying asphalt, and the baring technique use to treat the surface of CRC layer. These results can serve as important reference for the rational design of rigid-flexible composite asphalt pavements.
    publisherAmerican Society of Civil Engineers
    titleInterlaminar Shear Stress and Structure of Continuously Reinforced Concrete Composite Asphalt Pavements
    typeJournal Paper
    journal volume7
    journal issue4
    journal titleJournal of Highway and Transportation Research and Development (English Edition)
    identifier doi10.1061/JHTRCQ.0000341
    treeJournal of Highway and Transportation Research and Development (English Edition):;2013:;Volume ( 007 ):;issue: 004
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian