    Column Base Connections for Hollow Steel Sections: Seismic Performance and Strength Models

    Source: Journal of Structural Engineering:;2015:;Volume ( 141 ):;issue: 007
    Author:
    A. M. Kanvinde
    ,
    P. Higgins
    ,
    R. J. Cooke
    ,
    J. Perez
    ,
    J. Higgins
    DOI: 10.1061/(ASCE)ST.1943-541X.0001136
    Publisher: American Society of Civil Engineers
    Abstract: The seismic response of exposed hollow steel section columns to base plate connections is examined through a series of eight experiments. The prototype-scale tests investigate a range of variables including base plate size and thickness, column size, and anchor rod layout (four rods in two rows, and eight rods in three rows). The specimens were subjected to cyclic flexural loading and instrumented to provide direct (rather than inferred) measurement of tension forces in the anchor rods. All the specimens showed excellent deformation capacity, with a stable hysteretic response for base rotations as large as 0.057–0.13 rad. Three specimens failed by fracture of the weld between the column and the plate, whereas five did not fracture. Evaluation of the test data against the current design approach prevalent in the United States suggests that (1) the design approach is reasonably conservative but (2) does not address the effect of the third (i.e., central) row of anchor rods; as a result, it cannot be used to design them. A new design method is presented that explicitly incorporates the third row of rods. The new approach is evaluated against the test data and it is determined that the new approach reflects the internal mechanics of the connections in an improved way while providing more accurate estimates of forces in the rods. Recommendations for the design of the connections are outlined, along with ongoing work that leverages the deformation capacity of these connections for displacement-based design. The limitations of the study are summarized, especially in terms of challenges to the generalization of its findings.
    • Download: (3.234Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Column Base Connections for Hollow Steel Sections: Seismic Performance and Strength Models

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/71594
    Collections
    • Journal of Structural Engineering

    Show full item record

    contributor authorA. M. Kanvinde
    contributor authorP. Higgins
    contributor authorR. J. Cooke
    contributor authorJ. Perez
    contributor authorJ. Higgins
    date accessioned2017-05-08T22:06:46Z
    date available2017-05-08T22:06:46Z
    date copyrightJuly 2015
    date issued2015
    identifier other28792010.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/71594
    description abstractThe seismic response of exposed hollow steel section columns to base plate connections is examined through a series of eight experiments. The prototype-scale tests investigate a range of variables including base plate size and thickness, column size, and anchor rod layout (four rods in two rows, and eight rods in three rows). The specimens were subjected to cyclic flexural loading and instrumented to provide direct (rather than inferred) measurement of tension forces in the anchor rods. All the specimens showed excellent deformation capacity, with a stable hysteretic response for base rotations as large as 0.057–0.13 rad. Three specimens failed by fracture of the weld between the column and the plate, whereas five did not fracture. Evaluation of the test data against the current design approach prevalent in the United States suggests that (1) the design approach is reasonably conservative but (2) does not address the effect of the third (i.e., central) row of anchor rods; as a result, it cannot be used to design them. A new design method is presented that explicitly incorporates the third row of rods. The new approach is evaluated against the test data and it is determined that the new approach reflects the internal mechanics of the connections in an improved way while providing more accurate estimates of forces in the rods. Recommendations for the design of the connections are outlined, along with ongoing work that leverages the deformation capacity of these connections for displacement-based design. The limitations of the study are summarized, especially in terms of challenges to the generalization of its findings.
    publisherAmerican Society of Civil Engineers
    titleColumn Base Connections for Hollow Steel Sections: Seismic Performance and Strength Models
    typeJournal Paper
    journal volume141
    journal issue7
    journal titleJournal of Structural Engineering
    identifier doi10.1061/(ASCE)ST.1943-541X.0001136
    treeJournal of Structural Engineering:;2015:;Volume ( 141 ):;issue: 007
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian