    Performance and Characterization of Shear Ties for Use in Insulated Precast Concrete Sandwich Wall Panels

    Source: Journal of Structural Engineering:;2012:;Volume ( 138 ):;issue: 001
    Author:
    Clay Naito
    ,
    John Hoemann
    ,
    Mark Beacraft
    ,
    Bryan Bewick
    DOI: 10.1061/(ASCE)ST.1943-541X.0000430
    Publisher: American Society of Civil Engineers
    Abstract: Insulated precast concrete sandwich wall panels are commonly used for exterior cladding on building structures. The insulation is sandwiched between exterior and interior concrete layers to reduce the heating and cooling costs for the structure. The panels can be designed as composite, partially composite, or noncomposite. Shear ties are used to achieve these varying degrees of composite action between the interior and exterior concrete layers. A variety of shear ties are available for domestic construction. An experimental study was conducted to assess the relative strength and response of these commercially available ties. Fourteen different shear tie types were examined, the failure modes and responses were quantified, and simplified engineer level multilinear strength curves were developed for each connection. The test results indicate that shear ties used in sandwich wall construction have considerable variation in strength, stiffness, and deformability. The maximum shear strength of the discrete ties averaged 9.3 kN (2,100 lbf) with a minimum of 3.2 kN (730 lbf) and maximum of 18.4 kN (4,138 lbf). The ties exhibited elastic-brittle, elastic-plastic, and plastic-hardening responses. The results were used to develop trilinear constitutive relationships, which were used to approximate the flexural response of sandwich wall panels.
    • Download: (1.945Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Performance and Characterization of Shear Ties for Use in Insulated Precast Concrete Sandwich Wall Panels

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/68338
    Collections
    • Journal of Structural Engineering

    Show full item record

    contributor authorClay Naito
    contributor authorJohn Hoemann
    contributor authorMark Beacraft
    contributor authorBryan Bewick
    date accessioned2017-05-08T21:59:32Z
    date available2017-05-08T21:59:32Z
    date copyrightJanuary 2012
    date issued2012
    identifier other%28asce%29st%2E1943-541x%2E0000472.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/68338
    description abstractInsulated precast concrete sandwich wall panels are commonly used for exterior cladding on building structures. The insulation is sandwiched between exterior and interior concrete layers to reduce the heating and cooling costs for the structure. The panels can be designed as composite, partially composite, or noncomposite. Shear ties are used to achieve these varying degrees of composite action between the interior and exterior concrete layers. A variety of shear ties are available for domestic construction. An experimental study was conducted to assess the relative strength and response of these commercially available ties. Fourteen different shear tie types were examined, the failure modes and responses were quantified, and simplified engineer level multilinear strength curves were developed for each connection. The test results indicate that shear ties used in sandwich wall construction have considerable variation in strength, stiffness, and deformability. The maximum shear strength of the discrete ties averaged 9.3 kN (2,100 lbf) with a minimum of 3.2 kN (730 lbf) and maximum of 18.4 kN (4,138 lbf). The ties exhibited elastic-brittle, elastic-plastic, and plastic-hardening responses. The results were used to develop trilinear constitutive relationships, which were used to approximate the flexural response of sandwich wall panels.
    publisherAmerican Society of Civil Engineers
    titlePerformance and Characterization of Shear Ties for Use in Insulated Precast Concrete Sandwich Wall Panels
    typeJournal Paper
    journal volume138
    journal issue1
    journal titleJournal of Structural Engineering
    identifier doi10.1061/(ASCE)ST.1943-541X.0000430
    treeJournal of Structural Engineering:;2012:;Volume ( 138 ):;issue: 001
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian