    Modeling and Behavior of Steel Plate Connections Subject to Various Fire Scenarios

    Source: Journal of Structural Engineering:;2010:;Volume ( 136 ):;issue: 007
    Author:
    Maria E. Garlock
    ,
    Serdar Selamet
    DOI: 10.1061/(ASCE)ST.1943-541X.0000179
    Publisher: American Society of Civil Engineers
    Abstract: Shear connections are common connection types and they are designed to resist only shear loads. In a fire event, the axial restraint provided by adjacent structure creates unanticipated compressive and tensile forces in the beam and thus the connection. Using finite-element models, this study examines single-plate shear connections that are bolted to the beam and welded to the supporting girder. A floor subassembly, which includes the beam, girder, slab, and connection, is modeled so that appropriate forces are applied to the connection. The model is validated with the experiments of bolted lap splice plates at elevated temperatures, as well as full-scale experiments. This paper (1) illustrates efficient modeling methods for these floor subassemblies; (2) evaluates the importance of the slab in the connection response; and (3) examines the effects of the rate of heating and cooling on the connection. The results show that care needs to be taken as to how the concrete slab is represented in the model. The heating and cooling rates affect the beam stress distribution, peak temperatures, and peak displacements, but not the peak beam axial force. Also, the cooling phase creates large tensile forces in the connection which can lead to failure.
    • Download: (615.2Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Modeling and Behavior of Steel Plate Connections Subject to Various Fire Scenarios

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/68063
    Collections
    • Journal of Structural Engineering

    Show full item record

    contributor authorMaria E. Garlock
    contributor authorSerdar Selamet
    date accessioned2017-05-08T21:59:05Z
    date available2017-05-08T21:59:05Z
    date copyrightJuly 2010
    date issued2010
    identifier other%28asce%29st%2E1943-541x%2E0000218.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/68063
    description abstractShear connections are common connection types and they are designed to resist only shear loads. In a fire event, the axial restraint provided by adjacent structure creates unanticipated compressive and tensile forces in the beam and thus the connection. Using finite-element models, this study examines single-plate shear connections that are bolted to the beam and welded to the supporting girder. A floor subassembly, which includes the beam, girder, slab, and connection, is modeled so that appropriate forces are applied to the connection. The model is validated with the experiments of bolted lap splice plates at elevated temperatures, as well as full-scale experiments. This paper (1) illustrates efficient modeling methods for these floor subassemblies; (2) evaluates the importance of the slab in the connection response; and (3) examines the effects of the rate of heating and cooling on the connection. The results show that care needs to be taken as to how the concrete slab is represented in the model. The heating and cooling rates affect the beam stress distribution, peak temperatures, and peak displacements, but not the peak beam axial force. Also, the cooling phase creates large tensile forces in the connection which can lead to failure.
    publisherAmerican Society of Civil Engineers
    titleModeling and Behavior of Steel Plate Connections Subject to Various Fire Scenarios
    typeJournal Paper
    journal volume136
    journal issue7
    journal titleJournal of Structural Engineering
    identifier doi10.1061/(ASCE)ST.1943-541X.0000179
    treeJournal of Structural Engineering:;2010:;Volume ( 136 ):;issue: 007
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian