contributor author | Z. Ahmad | |
contributor author | B. Jain | |
contributor author | S. Kumar | |
contributor author | M. K. Mittal | |
date accessioned | 2017-05-08T21:58:00Z | |
date available | 2017-05-08T21:58:00Z | |
date copyright | May 2011 | |
date issued | 2011 | |
identifier other | %28asce%29ps%2E1949-1204%2E0000118.pdf | |
identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/67625 | |
description abstract | Water pumps used in pumped storage plant, drainage, agriculture, and industrial process experience operational problems such as vibration, impeller damage, and wear of bearing caused by nonaxial inflow of water in the suction pipe. Rational design of pump-sump and vortex breaker aligns the nonaxial flow in the axial direction and reduces these operational problems in the pump. This paper deals with state-of-the-art-design of a pump-sump and the criteria for its model testing. A | |
publisher | American Society of Civil Engineers | |
title | Rational Design of a Pump-Sump and Its Model Testing | |
type | Journal Paper | |
journal volume | 2 | |
journal issue | 2 | |
journal title | Journal of Pipeline Systems Engineering and Practice | |
identifier doi | 10.1061/(ASCE)PS.1949-1204.0000074 | |
tree | Journal of Pipeline Systems Engineering and Practice:;2011:;Volume ( 002 ):;issue: 002 | |
contenttype | Fulltext | |