Testing of Residential Homes under Wind LoadsSource: Natural Hazards Review:;2011:;Volume ( 012 ):;issue: 004Author:Emil Simiu
,
Girma Bitsuamlak
,
Arindam Gan Chowdhury
,
Ruilong Li
,
Amanuel Tecle
,
DongHun Yeo
DOI: 10.1061/(ASCE)NH.1527-6996.0000034Publisher: American Society of Civil Engineers
Abstract: Aerodynamic testing of low-rise structures is fraught with difficulties that can be the cause of large measurement errors, resulting in the underestimation of aerodynamic pressures by a factor of as much as two. The errors are primarily attributable to the inadequate knowledge and simulation of wind flows affecting low-rise buildings, especially residential homes in suburban environments. A type of aerodynamic testing of sufficiently small low-rise structures is explored that does not entail the simulation of the turbulence intensity and integral turbulence scales. That type of testing would offer several advantages: eliminating a major cause of discrepancies among measurements conducted in different laboratories, allowing the use of larger model scales, and allowing testing in both typical commercial wind tunnels and in open jet facilities of the Wall of Wind (WoW) type. Preliminary tests based on data obtained at the University of Western Ontario wind tunnel and the Florida International University large-scale six-fan WoW facility suggest that the proposed type of testing yields systematically conservative results for the specialized type of measurements considered herein. In most cases, but not all, the degree of conservatism is modest. The results appear to be of sufficient interest to warrant additional research.
|
Collections
Show full item record
| contributor author | Emil Simiu | |
| contributor author | Girma Bitsuamlak | |
| contributor author | Arindam Gan Chowdhury | |
| contributor author | Ruilong Li | |
| contributor author | Amanuel Tecle | |
| contributor author | DongHun Yeo | |
| date accessioned | 2017-05-08T21:57:33Z | |
| date available | 2017-05-08T21:57:33Z | |
| date copyright | November 2011 | |
| date issued | 2011 | |
| identifier other | %28asce%29nh%2E1527-6996%2E0000075.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/67430 | |
| description abstract | Aerodynamic testing of low-rise structures is fraught with difficulties that can be the cause of large measurement errors, resulting in the underestimation of aerodynamic pressures by a factor of as much as two. The errors are primarily attributable to the inadequate knowledge and simulation of wind flows affecting low-rise buildings, especially residential homes in suburban environments. A type of aerodynamic testing of sufficiently small low-rise structures is explored that does not entail the simulation of the turbulence intensity and integral turbulence scales. That type of testing would offer several advantages: eliminating a major cause of discrepancies among measurements conducted in different laboratories, allowing the use of larger model scales, and allowing testing in both typical commercial wind tunnels and in open jet facilities of the Wall of Wind (WoW) type. Preliminary tests based on data obtained at the University of Western Ontario wind tunnel and the Florida International University large-scale six-fan WoW facility suggest that the proposed type of testing yields systematically conservative results for the specialized type of measurements considered herein. In most cases, but not all, the degree of conservatism is modest. The results appear to be of sufficient interest to warrant additional research. | |
| publisher | American Society of Civil Engineers | |
| title | Testing of Residential Homes under Wind Loads | |
| type | Journal Paper | |
| journal volume | 12 | |
| journal issue | 4 | |
| journal title | Natural Hazards Review | |
| identifier doi | 10.1061/(ASCE)NH.1527-6996.0000034 | |
| tree | Natural Hazards Review:;2011:;Volume ( 012 ):;issue: 004 | |
| contenttype | Fulltext |