X-Ray Computed Tomography and Nondestructive Evaluation of Clogging in Porous Concrete Field SamplesSource: Journal of Materials in Civil Engineering:;2012:;Volume ( 024 ):;issue: 008Author:Kalehiwot Nega Manahiloh
,
Balasingam Muhunthan
,
Masoud Kayhanian
,
Seyoum Yami Gebremariam
DOI: 10.1061/(ASCE)MT.1943-5533.0000484Publisher: American Society of Civil Engineers
Abstract: This study aims to investigate and quantify the fraction of clogging in pervious concrete samples cored from parking lots. Image observation, analysis, and processing of representative cores retrieved from parking lots enabled qualitative relation of porosity with clogging. Porosity profiles obtained from processing of computed tomography (CT) scanned images were used to assess the nature and extent of clogging. Significantly lower porosity values were computed for old cores compared to newer ones. It was also observed that samples manifested clogged behavior because of high cement paste (mortar) content. Porosities of samples were calculated, for comparison using a gravimetric method and the clogged fraction in the cores was quantified by recalculating porosities of specimens scanned after vacuum cleaning. X-ray CT scanning proved a useful tool to study clogging, and the clogged fraction varied from 1.48% in sample PL 12-1 to 11.15% in sample QP 45-3.
|
Collections
Show full item record
| contributor author | Kalehiwot Nega Manahiloh | |
| contributor author | Balasingam Muhunthan | |
| contributor author | Masoud Kayhanian | |
| contributor author | Seyoum Yami Gebremariam | |
| date accessioned | 2017-05-08T21:55:53Z | |
| date available | 2017-05-08T21:55:53Z | |
| date copyright | August 2012 | |
| date issued | 2012 | |
| identifier other | %28asce%29mt%2E1943-5533%2E0000517.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/66861 | |
| description abstract | This study aims to investigate and quantify the fraction of clogging in pervious concrete samples cored from parking lots. Image observation, analysis, and processing of representative cores retrieved from parking lots enabled qualitative relation of porosity with clogging. Porosity profiles obtained from processing of computed tomography (CT) scanned images were used to assess the nature and extent of clogging. Significantly lower porosity values were computed for old cores compared to newer ones. It was also observed that samples manifested clogged behavior because of high cement paste (mortar) content. Porosities of samples were calculated, for comparison using a gravimetric method and the clogged fraction in the cores was quantified by recalculating porosities of specimens scanned after vacuum cleaning. X-ray CT scanning proved a useful tool to study clogging, and the clogged fraction varied from 1.48% in sample PL 12-1 to 11.15% in sample QP 45-3. | |
| publisher | American Society of Civil Engineers | |
| title | X-Ray Computed Tomography and Nondestructive Evaluation of Clogging in Porous Concrete Field Samples | |
| type | Journal Paper | |
| journal volume | 24 | |
| journal issue | 8 | |
| journal title | Journal of Materials in Civil Engineering | |
| identifier doi | 10.1061/(ASCE)MT.1943-5533.0000484 | |
| tree | Journal of Materials in Civil Engineering:;2012:;Volume ( 024 ):;issue: 008 | |
| contenttype | Fulltext |