    Polychromatic UV Fluence Measurement Using Chemical Actinometry, Biodosimetry, and Mathematical Techniques

    Source: Journal of Environmental Engineering:;2006:;Volume ( 132 ):;issue: 008
    Author:
    Shanshan Jin
    ,
    Alexander A. Mofidi
    ,
    Karl G. Linden
    DOI: 10.1061/(ASCE)0733-9372(2006)132:8(831)
    Publisher: American Society of Civil Engineers
    Abstract: With the growing acceptance of ultraviolet (UV) irradiation for disinfection of water and wastewater, the use of medium pressure Hg-based UV lamps and nonmercury, pulsed UV lamps emitting polychromatic light, are being considered in place of low-pressure, monochromatic UV lamps. However, traditional methods of fluence measurement developed for monochromatic light sources are not appropriate for polychromatic light sources. New approaches for estimation of effective germicidal fluence for polychromatic UV sources were investigated integrating chemical actinometry (uridine and iodide/iodate) with mathematical modeling. Actinometric fluence measurements as well as radiometry were referenced against microbial biodosimetry. Combining traditional chemical actinometry with mathematical analysis improved the accuracy of incident and germicidal polychromatic UV fluence measurement. Uridine actinometer germicidal fluence measurement, with or without mathematical correction, was just outside of the 95% confidence interval of that measured by biodosimetry. Similarly, an iodide/iodate actinometer was observed to accurately measure incident fluence, and coupled with mathematical corrections, it measured germicidal fluence within the 95% confidence interval of that measured by biodosimetry. These methods have potential to develop into flexible, convenient ways to measure germicidally effective UV fluence from any type of UV lamp.
    • Download: (323.7Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Polychromatic UV Fluence Measurement Using Chemical Actinometry, Biodosimetry, and Mathematical Techniques

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/66087
    Collections
    • Journal of Environmental Engineering

    Show full item record

    contributor authorShanshan Jin
    contributor authorAlexander A. Mofidi
    contributor authorKarl G. Linden
    date accessioned2017-05-08T21:54:27Z
    date available2017-05-08T21:54:27Z
    date copyrightAugust 2006
    date issued2006
    identifier other%28asce%290733-9372%282006%29132%3A8%28831%29.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/66087
    description abstractWith the growing acceptance of ultraviolet (UV) irradiation for disinfection of water and wastewater, the use of medium pressure Hg-based UV lamps and nonmercury, pulsed UV lamps emitting polychromatic light, are being considered in place of low-pressure, monochromatic UV lamps. However, traditional methods of fluence measurement developed for monochromatic light sources are not appropriate for polychromatic light sources. New approaches for estimation of effective germicidal fluence for polychromatic UV sources were investigated integrating chemical actinometry (uridine and iodide/iodate) with mathematical modeling. Actinometric fluence measurements as well as radiometry were referenced against microbial biodosimetry. Combining traditional chemical actinometry with mathematical analysis improved the accuracy of incident and germicidal polychromatic UV fluence measurement. Uridine actinometer germicidal fluence measurement, with or without mathematical correction, was just outside of the 95% confidence interval of that measured by biodosimetry. Similarly, an iodide/iodate actinometer was observed to accurately measure incident fluence, and coupled with mathematical corrections, it measured germicidal fluence within the 95% confidence interval of that measured by biodosimetry. These methods have potential to develop into flexible, convenient ways to measure germicidally effective UV fluence from any type of UV lamp.
    publisherAmerican Society of Civil Engineers
    titlePolychromatic UV Fluence Measurement Using Chemical Actinometry, Biodosimetry, and Mathematical Techniques
    typeJournal Paper
    journal volume132
    journal issue8
    journal titleJournal of Environmental Engineering
    identifier doi10.1061/(ASCE)0733-9372(2006)132:8(831)
    treeJournal of Environmental Engineering:;2006:;Volume ( 132 ):;issue: 008
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian