    External and Internal Corrosion of Large-Diameter Cast Iron Mains

    Source: Journal of Infrastructure Systems:;2013:;Volume ( 019 ):;issue: 004
    Author:
    Balvant Rajani
    ,
    Yehuda Kleiner
    DOI: 10.1061/(ASCE)IS.1943-555X.0000135
    Publisher: American Society of Civil Engineers
    Abstract: Deterioration in cast iron mains manifests itself in the form of corrosion. External corrosion is typically found to occur in pipes buried in corrosive soils while internal corrosion is dependent on water chemistry and flow characteristics. In the literature, corrosion of cast iron pipes (external and internal) is typically characterized by corrosion pit depth even though corroded area and corroded pit volume as well as pit location may enhance this characterization. Knowledge of these corrosion pit properties permits the assessment of its structural integrity. Typically, internal and external corrosion pits and corroded areas are observed to occur in many irregular shapes and sizes, which make their characterization a challenge. This paper describes extreme value statistical models that can be used to estimate external and internal corrosion pit depths in cast iron pipes using indirect properties or parameters. The goal of these corrosion models is to be able to predict corrosion pit depth based on available data with an acceptable degree of confidence. The external corrosion model is calibrated using external corrosion data collected by Thames Water Utilities Ltd (TWUL) and subsequently validated with data obtained from the inspection of four cast iron pipe lengths. The internal corrosion model was calibrated using internal corrosion data but sufficient appropriate data was not available for its validation.
    • Download: (1.217Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      External and Internal Corrosion of Large-Diameter Cast Iron Mains

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/65725
    Collections
    • Journal of Infrastructure Systems

    Show full item record

    contributor authorBalvant Rajani
    contributor authorYehuda Kleiner
    date accessioned2017-05-08T21:53:53Z
    date available2017-05-08T21:53:53Z
    date copyrightDecember 2013
    date issued2013
    identifier other%28asce%29is%2E1943-555x%2E0000165.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/65725
    description abstractDeterioration in cast iron mains manifests itself in the form of corrosion. External corrosion is typically found to occur in pipes buried in corrosive soils while internal corrosion is dependent on water chemistry and flow characteristics. In the literature, corrosion of cast iron pipes (external and internal) is typically characterized by corrosion pit depth even though corroded area and corroded pit volume as well as pit location may enhance this characterization. Knowledge of these corrosion pit properties permits the assessment of its structural integrity. Typically, internal and external corrosion pits and corroded areas are observed to occur in many irregular shapes and sizes, which make their characterization a challenge. This paper describes extreme value statistical models that can be used to estimate external and internal corrosion pit depths in cast iron pipes using indirect properties or parameters. The goal of these corrosion models is to be able to predict corrosion pit depth based on available data with an acceptable degree of confidence. The external corrosion model is calibrated using external corrosion data collected by Thames Water Utilities Ltd (TWUL) and subsequently validated with data obtained from the inspection of four cast iron pipe lengths. The internal corrosion model was calibrated using internal corrosion data but sufficient appropriate data was not available for its validation.
    publisherAmerican Society of Civil Engineers
    titleExternal and Internal Corrosion of Large-Diameter Cast Iron Mains
    typeJournal Paper
    journal volume19
    journal issue4
    journal titleJournal of Infrastructure Systems
    identifier doi10.1061/(ASCE)IS.1943-555X.0000135
    treeJournal of Infrastructure Systems:;2013:;Volume ( 019 ):;issue: 004
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian