    Study of the Xinanjiang Model Parameter Calibration

    Source: Journal of Hydrologic Engineering:;2013:;Volume ( 018 ):;issue: 011
    Author:
    Li Zhijia
    ,
    Xin Penglei
    ,
    Tang Jiahui
    DOI: 10.1061/(ASCE)HE.1943-5584.0000527
    Publisher: American Society of Civil Engineers
    Abstract: The Xinanjiang model parameter calibration is an optimization problem that aims to determine the values of model parameters that provide the best fit between observed and estimated flows. Many researchers have used the shuffled complex evolution (SCE-UA) algorithm in the Xinanjiang model parameter calibration and have found some problems in its application. Identifying methods in choosing an objective function, the amount of calibration data to be used, and the best calibration steps in searching for the best parameters are just some of the application problems that must be solved. The goal of the present study is to resolve the aforementioned problems. This work calibrates the Xinanjiang model for the Yuetan basin in China based on the SCE-UA method. In the objective function study, six objective functions are commonly used. Results demonstrate that the water quantity balance error function is the best choice in both daily and hourly Xinanjiang model calibrations. During the experiment, 20 sets of observed data with length differences of 1–20 years are used. The results reveal that data amounting to a period of 16 years are needed to obtain a relatively stable parameter set. Meanwhile, the objective optimization method is introduced in the calibration step study. This method combines the coupling of the objective optimization method with the SCE-UA algorithm. Parameter calibration results reveal that the combined method can increase the calibration speed and reduce the influence of the calibration data period on the results.
    • Download: (2.489Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Study of the Xinanjiang Model Parameter Calibration

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/63415
    Collections
    • Journal of Hydrologic Engineering

    Show full item record

    contributor authorLi Zhijia
    contributor authorXin Penglei
    contributor authorTang Jiahui
    date accessioned2017-05-08T21:49:17Z
    date available2017-05-08T21:49:17Z
    date copyrightNovember 2013
    date issued2013
    identifier other%28asce%29he%2E1943-5584%2E0000547.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/63415
    description abstractThe Xinanjiang model parameter calibration is an optimization problem that aims to determine the values of model parameters that provide the best fit between observed and estimated flows. Many researchers have used the shuffled complex evolution (SCE-UA) algorithm in the Xinanjiang model parameter calibration and have found some problems in its application. Identifying methods in choosing an objective function, the amount of calibration data to be used, and the best calibration steps in searching for the best parameters are just some of the application problems that must be solved. The goal of the present study is to resolve the aforementioned problems. This work calibrates the Xinanjiang model for the Yuetan basin in China based on the SCE-UA method. In the objective function study, six objective functions are commonly used. Results demonstrate that the water quantity balance error function is the best choice in both daily and hourly Xinanjiang model calibrations. During the experiment, 20 sets of observed data with length differences of 1–20 years are used. The results reveal that data amounting to a period of 16 years are needed to obtain a relatively stable parameter set. Meanwhile, the objective optimization method is introduced in the calibration step study. This method combines the coupling of the objective optimization method with the SCE-UA algorithm. Parameter calibration results reveal that the combined method can increase the calibration speed and reduce the influence of the calibration data period on the results.
    publisherAmerican Society of Civil Engineers
    titleStudy of the Xinanjiang Model Parameter Calibration
    typeJournal Paper
    journal volume18
    journal issue11
    journal titleJournal of Hydrologic Engineering
    identifier doi10.1061/(ASCE)HE.1943-5584.0000527
    treeJournal of Hydrologic Engineering:;2013:;Volume ( 018 ):;issue: 011
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian