    Performance of Wet Weather Treatment Facility for Control of Combined Sewer Overflows: Case Study in Cincinnati, Ohio

    Source: Journal of Environmental Engineering:;2005:;Volume ( 131 ):;issue: 003
    Author:
    Jeffrey G. Szabo
    ,
    Steven G. Buchberger
    ,
    Paul L. Bishop
    DOI: 10.1061/(ASCE)0733-9372(2005)131:3(375)
    Publisher: American Society of Civil Engineers
    Abstract: Efforts aimed at reducing pollutant loads from combined sewer overflows (CSOs) on the Muddy Creek receiving waters in Cincinnati, Ohio have been underway in recent years. This includes an investigation of the treatment performance of a flow-through wet weather treatment facility (WWTF) using off-line sedimentation tanks, fine screening and chemical disinfection (disinfection was inactive during this study). Calculations using hydrographs and water quality samples collected at the WWTF during rain events established the mass of biochemical oxygen demand
    • Download: (616.8Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Performance of Wet Weather Treatment Facility for Control of Combined Sewer Overflows: Case Study in Cincinnati, Ohio

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/62886
    Collections
    • Journal of Environmental Engineering

    Show full item record

    contributor authorJeffrey G. Szabo
    contributor authorSteven G. Buchberger
    contributor authorPaul L. Bishop
    date accessioned2017-05-08T21:48:22Z
    date available2017-05-08T21:48:22Z
    date copyrightMarch 2005
    date issued2005
    identifier other%28asce%290733-9372%282005%29131%3A3%28375%29.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/62886
    description abstractEfforts aimed at reducing pollutant loads from combined sewer overflows (CSOs) on the Muddy Creek receiving waters in Cincinnati, Ohio have been underway in recent years. This includes an investigation of the treatment performance of a flow-through wet weather treatment facility (WWTF) using off-line sedimentation tanks, fine screening and chemical disinfection (disinfection was inactive during this study). Calculations using hydrographs and water quality samples collected at the WWTF during rain events established the mass of biochemical oxygen demand
    publisherAmerican Society of Civil Engineers
    titlePerformance of Wet Weather Treatment Facility for Control of Combined Sewer Overflows: Case Study in Cincinnati, Ohio
    typeJournal Paper
    journal volume131
    journal issue3
    journal titleJournal of Environmental Engineering
    identifier doi10.1061/(ASCE)0733-9372(2005)131:3(375)
    treeJournal of Environmental Engineering:;2005:;Volume ( 131 ):;issue: 003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian