    Continuous In Situ Characterization of Particulate Sizes in Urban Stormwater: Method Testing and Refinement

    Source: Journal of Environmental Engineering:;2012:;Volume ( 138 ):;issue: 006
    Author:
    Jeffrey S. Brown
    ,
    Drew Ackerman
    ,
    Eric D. Stein
    DOI: 10.1061/(ASCE)EE.1943-7870.0000516
    Publisher: American Society of Civil Engineers
    Abstract: Understanding the size distribution of stormwater particulates and the pollutants associated with each size fraction is becoming an increasingly important aspect of stormwater management. This paper evaluates the accuracy of the Laser In Situ Scattering and Transmissometry (LISST 100x) particle analyzer and describes the adaptation of the instrument for use in urban stormwater assessment. The accuracy of the instrument was evaluated with known particle size standards of 5, 20, and 100 µm. While the mode of the size distribution corresponded with the average particle size indicated by the manufacturer, the weighted mean was 131%–141% of the average particle size of the standards. Measured concentrations of screened natural sediment (
    • Download: (384.4Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Continuous In Situ Characterization of Particulate Sizes in Urban Stormwater: Method Testing and Refinement

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/59950
    Collections
    • Journal of Environmental Engineering

    Show full item record

    contributor authorJeffrey S. Brown
    contributor authorDrew Ackerman
    contributor authorEric D. Stein
    date accessioned2017-05-08T21:42:10Z
    date available2017-05-08T21:42:10Z
    date copyrightJune 2012
    date issued2012
    identifier other%28asce%29ee%2E1943-7870%2E0000524.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/59950
    description abstractUnderstanding the size distribution of stormwater particulates and the pollutants associated with each size fraction is becoming an increasingly important aspect of stormwater management. This paper evaluates the accuracy of the Laser In Situ Scattering and Transmissometry (LISST 100x) particle analyzer and describes the adaptation of the instrument for use in urban stormwater assessment. The accuracy of the instrument was evaluated with known particle size standards of 5, 20, and 100 µm. While the mode of the size distribution corresponded with the average particle size indicated by the manufacturer, the weighted mean was 131%–141% of the average particle size of the standards. Measured concentrations of screened natural sediment (
    publisherAmerican Society of Civil Engineers
    titleContinuous In Situ Characterization of Particulate Sizes in Urban Stormwater: Method Testing and Refinement
    typeJournal Paper
    journal volume138
    journal issue6
    journal titleJournal of Environmental Engineering
    identifier doi10.1061/(ASCE)EE.1943-7870.0000516
    treeJournal of Environmental Engineering:;2012:;Volume ( 138 ):;issue: 006
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian