    CFRP Tendons for the Repair of Posttensioned, Unbonded Concrete Buildings

    Source: Journal of Performance of Constructed Facilities:;2011:;Volume ( 025 ):;issue: 003
    Author:
    Colin MacDougall
    ,
    Mark Green
    ,
    Lucio Amato
    DOI: 10.1061/(ASCE)CF.1943-5509.0000146
    Publisher: American Society of Civil Engineers
    Abstract: The deterioration attributable to corrosion of concrete structures reinforced with unbonded, posttensioned tendons is a costly problem. Recent research has shown composite materials such as fiber-reinforced polymers (FRP) to be suitable alternatives to steel because they provide similar strength without susceptibility to electrochemical corrosion. Carbon-FRP (CFRP) in particular has great promise for prestressed applications because it shows resistance to corrosion in environments that might be encountered in concrete and experiences less relaxation than steel. This paper outlines the testing and implementation of a posttensioned system that uses CFRP tendons to replace corroded, unbonded posttensioned steel tendons. This system was then implemented in a parking garage in downtown Toronto. To the writers’ knowledge, this is the first example of an unbonded, posttensioned tendon replacement using FRP tendons. The system used split-wedge anchors designed specifically for CFRP tendons. The dead end was anchored by directly bonding the tendon to the concrete slab. The CFRP tendon was successfully inserted in the opening created by the removal of the corroded tendon and stressed. Although the system was shown to be feasible, the current anchorage configuration results in load losses of up to 60% during the transfer. Changing the orientation of the anchor was found to reduce the load loss to an acceptable range of 1–9%.
    • Download: (597.8Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      CFRP Tendons for the Repair of Posttensioned, Unbonded Concrete Buildings

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/57738
    Collections
    • Journal of Performance of Constructed Facilities

    Show full item record

    contributor authorColin MacDougall
    contributor authorMark Green
    contributor authorLucio Amato
    date accessioned2017-05-08T21:37:22Z
    date available2017-05-08T21:37:22Z
    date copyrightJune 2011
    date issued2011
    identifier other%28asce%29cf%2E1943-5509%2E0000149.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/57738
    description abstractThe deterioration attributable to corrosion of concrete structures reinforced with unbonded, posttensioned tendons is a costly problem. Recent research has shown composite materials such as fiber-reinforced polymers (FRP) to be suitable alternatives to steel because they provide similar strength without susceptibility to electrochemical corrosion. Carbon-FRP (CFRP) in particular has great promise for prestressed applications because it shows resistance to corrosion in environments that might be encountered in concrete and experiences less relaxation than steel. This paper outlines the testing and implementation of a posttensioned system that uses CFRP tendons to replace corroded, unbonded posttensioned steel tendons. This system was then implemented in a parking garage in downtown Toronto. To the writers’ knowledge, this is the first example of an unbonded, posttensioned tendon replacement using FRP tendons. The system used split-wedge anchors designed specifically for CFRP tendons. The dead end was anchored by directly bonding the tendon to the concrete slab. The CFRP tendon was successfully inserted in the opening created by the removal of the corroded tendon and stressed. Although the system was shown to be feasible, the current anchorage configuration results in load losses of up to 60% during the transfer. Changing the orientation of the anchor was found to reduce the load loss to an acceptable range of 1–9%.
    publisherAmerican Society of Civil Engineers
    titleCFRP Tendons for the Repair of Posttensioned, Unbonded Concrete Buildings
    typeJournal Paper
    journal volume25
    journal issue3
    journal titleJournal of Performance of Constructed Facilities
    identifier doi10.1061/(ASCE)CF.1943-5509.0000146
    treeJournal of Performance of Constructed Facilities:;2011:;Volume ( 025 ):;issue: 003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian