    Investigation of a Pavement Premature Failure on a Weak and Moisture Susceptible Base

    Source: Journal of Performance of Constructed Facilities:;2009:;Volume ( 023 ):;issue: 005
    Author:
    Dar-Hao Chen
    DOI: 10.1061/(ASCE)CF.1943-5509.0000040
    Publisher: American Society of Civil Engineers
    Abstract: An investigation was conducted to determine the root cause of the premature pavement failure. The premature pavement failure occurred in the form of rutting and alligator cracking. Although the affected portion was repaired by removing and replacing the top 75-mm asphalt concrete (AC), the repaired AC experienced recurring rutting and alligator cracking in a few weeks. Through extensive field and lab testing, it was found that the weak base is the root cause of the premature failure and the brittleness of the AC is secondary. However, both the base and AC were built according to plan and met the current material and field density requirements. It was concluded that density alone for construction quality control is not sufficient, as it was not able to protect against premature failures from occurring. Although there are many different ways to minimize premature failures, an immediate action is to include proof rolling in construction quality control. Proof rolling has been used with success to ensure proper compaction and to locate unstable areas, as the stability is greatly influenced by the degree of densification achieved during compaction.
    • Download: (340.6Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Investigation of a Pavement Premature Failure on a Weak and Moisture Susceptible Base

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/57628
    Collections
    • Journal of Performance of Constructed Facilities

    Show full item record

    contributor authorDar-Hao Chen
    date accessioned2017-05-08T21:37:12Z
    date available2017-05-08T21:37:12Z
    date copyrightOctober 2009
    date issued2009
    identifier other%28asce%29cf%2E1943-5509%2E0000043.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/57628
    description abstractAn investigation was conducted to determine the root cause of the premature pavement failure. The premature pavement failure occurred in the form of rutting and alligator cracking. Although the affected portion was repaired by removing and replacing the top 75-mm asphalt concrete (AC), the repaired AC experienced recurring rutting and alligator cracking in a few weeks. Through extensive field and lab testing, it was found that the weak base is the root cause of the premature failure and the brittleness of the AC is secondary. However, both the base and AC were built according to plan and met the current material and field density requirements. It was concluded that density alone for construction quality control is not sufficient, as it was not able to protect against premature failures from occurring. Although there are many different ways to minimize premature failures, an immediate action is to include proof rolling in construction quality control. Proof rolling has been used with success to ensure proper compaction and to locate unstable areas, as the stability is greatly influenced by the degree of densification achieved during compaction.
    publisherAmerican Society of Civil Engineers
    titleInvestigation of a Pavement Premature Failure on a Weak and Moisture Susceptible Base
    typeJournal Paper
    journal volume23
    journal issue5
    journal titleJournal of Performance of Constructed Facilities
    identifier doi10.1061/(ASCE)CF.1943-5509.0000040
    treeJournal of Performance of Constructed Facilities:;2009:;Volume ( 023 ):;issue: 005
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian