    Response of Beam-To-Column Web Cleated Joints For FRP Pultruded Members

    Source: Journal of Composites for Construction:;2014:;Volume ( 018 ):;issue: 002
    Author:
    Jawed Qureshi
    ,
    J. Toby Mottram
    DOI: 10.1061/(ASCE)CC.1943-5614.0000392
    Publisher: American Society of Civil Engineers
    Abstract: Physical testing is used to characterize the structural properties of beam-to-column joints, comprising pultruded fiber-reinforced polymer (FRP) H-shapes of depth 203 mm, connected by 128 mm-long web cleats and two M16 bolts per leg. Testing is performed on two batches of nominally identical specimens. One batch had web cleats of pultruded FRP and the other had structural steel. The structural behavior of the joints is based on their moment-rotation responses, failure modes, and serviceability vertical deflection limits. Joints with FRP cleats failed by delamination cracking at the top of the cleats, and when the cleats were of steel, the FRP failure occurred inside the column members. Neither failure mode is reported in the design manuals from pultruders. At the onset of the FRP damage, it was found that the steel joints were twice as stiff as the FRP joints. On the basis of a characteristic (damage) rotation, calculated in accordance with Eurocode 0, the serviceability deflection limits are established to be span/300 and span/650 for the joints with FRP and steel cleats, respectively. This finding suggests that appropriate deflection limits, in relation to cleated connections, should be proposed in manufactures’ design manuals and relative design standards and design codes. Failure to address the serviceability, by the engineer of record, could lead to unreliable designs.
    • Download: (3.102Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Response of Beam-To-Column Web Cleated Joints For FRP Pultruded Members

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/57536
    Collections
    • Journal of Composites for Construction

    Show full item record

    contributor authorJawed Qureshi
    contributor authorJ. Toby Mottram
    date accessioned2017-05-08T21:36:51Z
    date available2017-05-08T21:36:51Z
    date copyrightApril 2014
    date issued2014
    identifier other%28asce%29cc%2E1943-5614%2E0000395.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/57536
    description abstractPhysical testing is used to characterize the structural properties of beam-to-column joints, comprising pultruded fiber-reinforced polymer (FRP) H-shapes of depth 203 mm, connected by 128 mm-long web cleats and two M16 bolts per leg. Testing is performed on two batches of nominally identical specimens. One batch had web cleats of pultruded FRP and the other had structural steel. The structural behavior of the joints is based on their moment-rotation responses, failure modes, and serviceability vertical deflection limits. Joints with FRP cleats failed by delamination cracking at the top of the cleats, and when the cleats were of steel, the FRP failure occurred inside the column members. Neither failure mode is reported in the design manuals from pultruders. At the onset of the FRP damage, it was found that the steel joints were twice as stiff as the FRP joints. On the basis of a characteristic (damage) rotation, calculated in accordance with Eurocode 0, the serviceability deflection limits are established to be span/300 and span/650 for the joints with FRP and steel cleats, respectively. This finding suggests that appropriate deflection limits, in relation to cleated connections, should be proposed in manufactures’ design manuals and relative design standards and design codes. Failure to address the serviceability, by the engineer of record, could lead to unreliable designs.
    publisherAmerican Society of Civil Engineers
    titleResponse of Beam-To-Column Web Cleated Joints For FRP Pultruded Members
    typeJournal Paper
    journal volume18
    journal issue2
    journal titleJournal of Composites for Construction
    identifier doi10.1061/(ASCE)CC.1943-5614.0000392
    treeJournal of Composites for Construction:;2014:;Volume ( 018 ):;issue: 002
    contenttypeFulltext