    Flexural Performance of Carbon Fiber-Reinforced Polymer Prestressed Concrete Side-by-Side Box Beam Bridge

    Source: Journal of Composites for Construction:;2011:;Volume ( 015 ):;issue: 005
    Author:
    Nabil F. Grace
    ,
    Elin A. Jensen
    ,
    Delali K. Noamesi
    DOI: 10.1061/(ASCE)CC.1943-5614.0000207
    Publisher: American Society of Civil Engineers
    Abstract: The effect of varying transverse posttensioning levels and arrangements on the load response of a one-half scale 30° skewed seven box beam bridge model was investigated. The effective span of the bridge model was 9.45 m (31 ft) with a width of 3.35 m (11 ft) and depth of 355.6 mm (14 in.). The bridge model was prestressed and reinforced with carbon fiber composite cables (CFCCs). CFCCs were also used as shear reinforcement. The bridge model was provided with five transverse diaphragms equally spaced along the length of the bridge. The experimental investigation included load and strain distribution tests and a flexural ultimate load test. The load and strain distribution tests were conducted on the bridge model with and without full-depth longitudinal cracks at the shear-key locations. The investigation showed that the application of an adequate transverse posttensioning force was successful in restoring the load distribution of the bridge model with full-depth longitudinal deck cracks to that of the case without deck cracks. The ultimate load and the associated compression-controlled failure mode of the bridge model agreed well with that predicted according to ACI 440.4R-04 and numerical analysis. The behavior of the bonded pretensioned and reinforced CFCC strands was linear elastic and remained intact throughout the collapse of the bridge model. The unbonded transverse posttensioned CFCC strand also remained intact.
    • Download: (2.314Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Flexural Performance of Carbon Fiber-Reinforced Polymer Prestressed Concrete Side-by-Side Box Beam Bridge

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/57333
    Collections
    • Journal of Composites for Construction

    Show full item record

    contributor authorNabil F. Grace
    contributor authorElin A. Jensen
    contributor authorDelali K. Noamesi
    date accessioned2017-05-08T21:36:23Z
    date available2017-05-08T21:36:23Z
    date copyrightOctober 2011
    date issued2011
    identifier other%28asce%29cc%2E1943-5614%2E0000210.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/57333
    description abstractThe effect of varying transverse posttensioning levels and arrangements on the load response of a one-half scale 30° skewed seven box beam bridge model was investigated. The effective span of the bridge model was 9.45 m (31 ft) with a width of 3.35 m (11 ft) and depth of 355.6 mm (14 in.). The bridge model was prestressed and reinforced with carbon fiber composite cables (CFCCs). CFCCs were also used as shear reinforcement. The bridge model was provided with five transverse diaphragms equally spaced along the length of the bridge. The experimental investigation included load and strain distribution tests and a flexural ultimate load test. The load and strain distribution tests were conducted on the bridge model with and without full-depth longitudinal cracks at the shear-key locations. The investigation showed that the application of an adequate transverse posttensioning force was successful in restoring the load distribution of the bridge model with full-depth longitudinal deck cracks to that of the case without deck cracks. The ultimate load and the associated compression-controlled failure mode of the bridge model agreed well with that predicted according to ACI 440.4R-04 and numerical analysis. The behavior of the bonded pretensioned and reinforced CFCC strands was linear elastic and remained intact throughout the collapse of the bridge model. The unbonded transverse posttensioned CFCC strand also remained intact.
    publisherAmerican Society of Civil Engineers
    titleFlexural Performance of Carbon Fiber-Reinforced Polymer Prestressed Concrete Side-by-Side Box Beam Bridge
    typeJournal Paper
    journal volume15
    journal issue5
    journal titleJournal of Composites for Construction
    identifier doi10.1061/(ASCE)CC.1943-5614.0000207
    treeJournal of Composites for Construction:;2011:;Volume ( 015 ):;issue: 005
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian