    Behavior of RC Beams Shear Strengthened with Bonded or Unbonded FRP Wraps

    Source: Journal of Composites for Construction:;2009:;Volume ( 013 ):;issue: 005
    Author:
    J. G. Teng
    ,
    G. M. Chen
    ,
    J. F. Chen
    ,
    O. A. Rosenboom
    ,
    L. Lam
    DOI: 10.1061/(ASCE)CC.1943-5614.0000040
    Publisher: American Society of Civil Engineers
    Abstract: Reinforced concrete (RC) beams shear-strengthened with fiber-reinforced polymer (FRP) fully wrapped around the member usually fail due to rupture of FRP, commonly preceded by gradual debonding of the FRP from the beam sides. To gain a better understanding of the shear resistance mechanism of such beams, particularly the interaction between the FRP, concrete, and internal steel stirrups, nine beams were tested in the present study: three as control specimens, three with bonded FRP full wraps, and three with FRP full wraps left unbonded to the beam sides. The use of unbonded wraps was aimed at a reliable estimation of the FRP contribution to shear resistance of the beam and how bonding affects this contribution. The test results show that the unbonded FRP wraps have a slightly higher shear strength contribution than the bonded FRP wraps, and that for both types of FRP wraps, the strain distributions along the critical shear crack are close to parabolic at the ultimate state. FRP rupture of the strengthened beams occurred at a value of maximum FRP strain considerably lower than the rupture strain found from tensile tests of flat coupons, which may be attributed to the effects of the dynamic debonding process and deformation of the FRP wraps due to the relative movements between the two sides of the critical shear crack. Test results also suggest that while the internal steel stirrups are fully used at beam shear failure by FRP rupture, the contribution of the concrete to the shear capacity may be adversely affected at high values of tensile strain in FRP wraps.
    • Download: (331.0Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Behavior of RC Beams Shear Strengthened with Bonded or Unbonded FRP Wraps

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/57154
    Collections
    • Journal of Composites for Construction

    Show full item record

    contributor authorJ. G. Teng
    contributor authorG. M. Chen
    contributor authorJ. F. Chen
    contributor authorO. A. Rosenboom
    contributor authorL. Lam
    date accessioned2017-05-08T21:36:04Z
    date available2017-05-08T21:36:04Z
    date copyrightOctober 2009
    date issued2009
    identifier other%28asce%29cc%2E1943-5614%2E0000043.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/57154
    description abstractReinforced concrete (RC) beams shear-strengthened with fiber-reinforced polymer (FRP) fully wrapped around the member usually fail due to rupture of FRP, commonly preceded by gradual debonding of the FRP from the beam sides. To gain a better understanding of the shear resistance mechanism of such beams, particularly the interaction between the FRP, concrete, and internal steel stirrups, nine beams were tested in the present study: three as control specimens, three with bonded FRP full wraps, and three with FRP full wraps left unbonded to the beam sides. The use of unbonded wraps was aimed at a reliable estimation of the FRP contribution to shear resistance of the beam and how bonding affects this contribution. The test results show that the unbonded FRP wraps have a slightly higher shear strength contribution than the bonded FRP wraps, and that for both types of FRP wraps, the strain distributions along the critical shear crack are close to parabolic at the ultimate state. FRP rupture of the strengthened beams occurred at a value of maximum FRP strain considerably lower than the rupture strain found from tensile tests of flat coupons, which may be attributed to the effects of the dynamic debonding process and deformation of the FRP wraps due to the relative movements between the two sides of the critical shear crack. Test results also suggest that while the internal steel stirrups are fully used at beam shear failure by FRP rupture, the contribution of the concrete to the shear capacity may be adversely affected at high values of tensile strain in FRP wraps.
    publisherAmerican Society of Civil Engineers
    titleBehavior of RC Beams Shear Strengthened with Bonded or Unbonded FRP Wraps
    typeJournal Paper
    journal volume13
    journal issue5
    journal titleJournal of Composites for Construction
    identifier doi10.1061/(ASCE)CC.1943-5614.0000040
    treeJournal of Composites for Construction:;2009:;Volume ( 013 ):;issue: 005
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian