    Hydraulic Calibration and Fluence Determination of Model Ultraviolet Disinfection System

    Source: Journal of Environmental Engineering:;2002:;Volume ( 128 ):;issue: 011
    Author:
    Trevor S. Dykstra
    ,
    Christian Chauret
    ,
    Graham A. Gagnon
    DOI: 10.1061/(ASCE)0733-9372(2002)128:11(1046)
    Publisher: American Society of Civil Engineers
    Abstract: The objective of this project was to determine the impact hydraulic dispersion has on the calibration of a flow-though model ultraviolet (UV)-disinfection system with chemical actinometry (potassium ferrioxalate) and MS 2 bacteriophage. Fluence was supplied by a medium-pressure ultraviolet lamp to a quartz tube (19 mm diameter) situated in a ventilated galvanized casing. The UV lamp was attached to a vertical position guide, for UV fluence to be varied by positioning the UV lamp at various vertical heights above the quartz tube. Water was pumped through the quartz tube at rates of 100–300 mL/min. An in-line pipe mixer was installed prior to the UV system to ensure adequate mixing with the bulk liquid and chemical actinometer and to mitigate jet formation within the quartz tube. Tracer studies were conducted with and without the in-line mixer using potassium chloride (3 mM). Dispersion coefficients were obtained from the tracer study and incorporated into an axial-dispersion model to determine the rate coefficient of potassium ferrioxalate in the model UV system. A numerical model was used to determine the fluence supplied by the lamp with a reduction in exposure time. After dispersion and kinetics are accounted for within the UV system, the model predicted UV fluence that was in general agreement with UV design curves for inactivation MS 2 bacteriophage. The differences in the design curves and the fluence–response model in the present investigation were found to be related to the experimental errors introduced from using a flowing system and because a medium pressure lamp was used in the present investigation.
    • Download: (144.2Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Hydraulic Calibration and Fluence Determination of Model Ultraviolet Disinfection System

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/56353
    Collections
    • Journal of Environmental Engineering

    Show full item record

    contributor authorTrevor S. Dykstra
    contributor authorChristian Chauret
    contributor authorGraham A. Gagnon
    date accessioned2017-05-08T21:33:58Z
    date available2017-05-08T21:33:58Z
    date copyrightNovember 2002
    date issued2002
    identifier other%28asce%290733-9372%282002%29128%3A11%281046%29.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/56353
    description abstractThe objective of this project was to determine the impact hydraulic dispersion has on the calibration of a flow-though model ultraviolet (UV)-disinfection system with chemical actinometry (potassium ferrioxalate) and MS 2 bacteriophage. Fluence was supplied by a medium-pressure ultraviolet lamp to a quartz tube (19 mm diameter) situated in a ventilated galvanized casing. The UV lamp was attached to a vertical position guide, for UV fluence to be varied by positioning the UV lamp at various vertical heights above the quartz tube. Water was pumped through the quartz tube at rates of 100–300 mL/min. An in-line pipe mixer was installed prior to the UV system to ensure adequate mixing with the bulk liquid and chemical actinometer and to mitigate jet formation within the quartz tube. Tracer studies were conducted with and without the in-line mixer using potassium chloride (3 mM). Dispersion coefficients were obtained from the tracer study and incorporated into an axial-dispersion model to determine the rate coefficient of potassium ferrioxalate in the model UV system. A numerical model was used to determine the fluence supplied by the lamp with a reduction in exposure time. After dispersion and kinetics are accounted for within the UV system, the model predicted UV fluence that was in general agreement with UV design curves for inactivation MS 2 bacteriophage. The differences in the design curves and the fluence–response model in the present investigation were found to be related to the experimental errors introduced from using a flowing system and because a medium pressure lamp was used in the present investigation.
    publisherAmerican Society of Civil Engineers
    titleHydraulic Calibration and Fluence Determination of Model Ultraviolet Disinfection System
    typeJournal Paper
    journal volume128
    journal issue11
    journal titleJournal of Environmental Engineering
    identifier doi10.1061/(ASCE)0733-9372(2002)128:11(1046)
    treeJournal of Environmental Engineering:;2002:;Volume ( 128 ):;issue: 011
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian