YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASCE
    • Journal of Environmental Engineering
    • View Item
    •   YE&T Library
    • ASCE
    • Journal of Environmental Engineering
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Gas-Liquid Mass Transfer along Small Sewer Reaches

    Source: Journal of Environmental Engineering:;2001:;Volume ( 127 ):;issue: 005
    Author:
    Jacek A. Koziel
    ,
    Richard L. Corsi
    ,
    Desmond F. Lawler
    DOI: 10.1061/(ASCE)0733-9372(2001)127:5(430)
    Publisher: American Society of Civil Engineers
    Abstract: Municipal and industrial sewers may be localized sources of volatile organic compound (VOC) emissions to the ambient atmosphere. Previous studies of VOC emissions from sewers have focused on sewers with large diameters that are often characterized as having mild channel slopes and as conveying relatively large wastewater flow rates. The study described in this paper was completed to better understand VOC emissions from sewer reaches with small diameters, steep channel slopes, and relatively low wastewater flow rates (e.g., as might be typical for building laterals, street sewers, and on-site industrial sewers). Mathematical models were developed to investigate the nature of mass transfer kinetics and equilibrium conditions in such sewers. A series of 20 experiments were then completed to determine liquid-phase and gas-phase mass transfer coefficients for a range of sewer operating conditions and chemical properties. Experiments were completed in an experimental sewer reach (60 m length, 0.2 m diameter) using five volatile chemicals (acetone, ethyl acetate, toluene, ethylbenzene, and cyclohexane, listed in order of increasing Henry's law constants). Experimental stripping efficiencies were as high as 47% for cyclohexane and as low as 0.3% for acetone. Experimental and mathematical results indicate that VOCs with low Henry's law constants (e.g., acetone) can reach equilibrium conditions rapidly in sewers. However, emissions of VOCs with high Henry's law constants (e.g., cyclohexane) are kinetically limited, allowing for the sewer to be treated as an “open” system. The findings described herein suggest that a large fraction of VOCs with high Henry's law constants may be emitted to the ambient atmosphere in the near vicinity to the point of discharge.
    • Download: (115.0Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Gas-Liquid Mass Transfer along Small Sewer Reaches

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/55398
    Collections
    • Journal of Environmental Engineering

    Show full item record

    contributor authorJacek A. Koziel
    contributor authorRichard L. Corsi
    contributor authorDesmond F. Lawler
    date accessioned2017-05-08T21:32:25Z
    date available2017-05-08T21:32:25Z
    date copyrightMay 2001
    date issued2001
    identifier other%28asce%290733-9372%282001%29127%3A5%28430%29.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/55398
    description abstractMunicipal and industrial sewers may be localized sources of volatile organic compound (VOC) emissions to the ambient atmosphere. Previous studies of VOC emissions from sewers have focused on sewers with large diameters that are often characterized as having mild channel slopes and as conveying relatively large wastewater flow rates. The study described in this paper was completed to better understand VOC emissions from sewer reaches with small diameters, steep channel slopes, and relatively low wastewater flow rates (e.g., as might be typical for building laterals, street sewers, and on-site industrial sewers). Mathematical models were developed to investigate the nature of mass transfer kinetics and equilibrium conditions in such sewers. A series of 20 experiments were then completed to determine liquid-phase and gas-phase mass transfer coefficients for a range of sewer operating conditions and chemical properties. Experiments were completed in an experimental sewer reach (60 m length, 0.2 m diameter) using five volatile chemicals (acetone, ethyl acetate, toluene, ethylbenzene, and cyclohexane, listed in order of increasing Henry's law constants). Experimental stripping efficiencies were as high as 47% for cyclohexane and as low as 0.3% for acetone. Experimental and mathematical results indicate that VOCs with low Henry's law constants (e.g., acetone) can reach equilibrium conditions rapidly in sewers. However, emissions of VOCs with high Henry's law constants (e.g., cyclohexane) are kinetically limited, allowing for the sewer to be treated as an “open” system. The findings described herein suggest that a large fraction of VOCs with high Henry's law constants may be emitted to the ambient atmosphere in the near vicinity to the point of discharge.
    publisherAmerican Society of Civil Engineers
    titleGas-Liquid Mass Transfer along Small Sewer Reaches
    typeJournal Paper
    journal volume127
    journal issue5
    journal titleJournal of Environmental Engineering
    identifier doi10.1061/(ASCE)0733-9372(2001)127:5(430)
    treeJournal of Environmental Engineering:;2001:;Volume ( 127 ):;issue: 005
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian