    Effects of Variation of Axial Load and Bidirectional Loading on Seismic Performance of GFRP Retrofitted Reinforced Concrete Exterior Beam-Column Joints

    Source: Journal of Composites for Construction:;2010:;Volume ( 014 ):;issue: 001
    Author:
    Umut Akguzel
    ,
    Stefano Pampanin
    DOI: 10.1061/(ASCE)1090-0268(2010)14:1(94)
    Publisher: American Society of Civil Engineers
    Abstract: Most of the experimental studies available in literature on the seismic assessment and retrofit of existing, poorly detailed, reinforced concrete (RC) beam-column joints, typical of pre-1970s construction practice, have concentrated on the two-dimensional (2D) response, using unidirectional cyclic loading testing protocol and constant axial load. Even more limited information is available on the performance of exterior (corner) three-dimensional (3D) RC beam-column joints with substandard detailing subjected to bidirectional loading regime. In this study, the results of a comprehensive experimental program is presented, aiming to show the effects of varying axial and bidirectional loading on the seismic performance of deficient exterior RC beam-column joints before and after retrofit. Ten exterior beam-column joint subassemblies are tested, including four as-built specimens and six retrofitted specimens using externally bonded glass fiber-reinforced polymer (GFRP) sheets. Test results are herein presented and conclusions are drawn on the basis of the observed global and local performance. The significance of the triaxial interaction of varying axial and bidirectional loading effects on the response of retrofitted corner joints is confirmed by the experimental findings. The proposed retrofit solution was shown to be capable of re-establishing an appropriate hierarchy of strength within the subassembly, protecting the panel zone region from shear failure while promoting the formation of a plastic hinge in the beam.
    • Download: (1.697Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Effects of Variation of Axial Load and Bidirectional Loading on Seismic Performance of GFRP Retrofitted Reinforced Concrete Exterior Beam-Column Joints

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/54604
    Collections
    • Journal of Composites for Construction

    Show full item record

    contributor authorUmut Akguzel
    contributor authorStefano Pampanin
    date accessioned2017-05-08T21:31:13Z
    date available2017-05-08T21:31:13Z
    date copyrightFebruary 2010
    date issued2010
    identifier other%28asce%291090-0268%282010%2914%3A1%2894%29.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/54604
    description abstractMost of the experimental studies available in literature on the seismic assessment and retrofit of existing, poorly detailed, reinforced concrete (RC) beam-column joints, typical of pre-1970s construction practice, have concentrated on the two-dimensional (2D) response, using unidirectional cyclic loading testing protocol and constant axial load. Even more limited information is available on the performance of exterior (corner) three-dimensional (3D) RC beam-column joints with substandard detailing subjected to bidirectional loading regime. In this study, the results of a comprehensive experimental program is presented, aiming to show the effects of varying axial and bidirectional loading on the seismic performance of deficient exterior RC beam-column joints before and after retrofit. Ten exterior beam-column joint subassemblies are tested, including four as-built specimens and six retrofitted specimens using externally bonded glass fiber-reinforced polymer (GFRP) sheets. Test results are herein presented and conclusions are drawn on the basis of the observed global and local performance. The significance of the triaxial interaction of varying axial and bidirectional loading effects on the response of retrofitted corner joints is confirmed by the experimental findings. The proposed retrofit solution was shown to be capable of re-establishing an appropriate hierarchy of strength within the subassembly, protecting the panel zone region from shear failure while promoting the formation of a plastic hinge in the beam.
    publisherAmerican Society of Civil Engineers
    titleEffects of Variation of Axial Load and Bidirectional Loading on Seismic Performance of GFRP Retrofitted Reinforced Concrete Exterior Beam-Column Joints
    typeJournal Paper
    journal volume14
    journal issue1
    journal titleJournal of Composites for Construction
    identifier doi10.1061/(ASCE)1090-0268(2010)14:1(94)
    treeJournal of Composites for Construction:;2010:;Volume ( 014 ):;issue: 001
    contenttypeFulltext