    Archive

    Retrofit of a Three-Span Slab Bridge with Fiber Reinforced Polymer Systems—Testing and Rating

    Source: Journal of Composites for Construction:;2004:;Volume ( 008 ):;issue: 003
    Author:
    Bahram M. Shahrooz
    ,
    Serpil Boy
    DOI: 10.1061/(ASCE)1090-0268(2004)8:3(241)
    Publisher: American Society of Civil Engineers
    Abstract: A 45-year old, three-span reinforced concrete slab bridge with insufficient capacity was retrofitted with 76.2- and 127-mm wide bonded carbon fiber-reinforced polymer (FRP) plates, 102-mm wide bonded carbon FRP plates with mechanical anchors at the ends, and bonded carbon FRP fabrics. The use of four systems in one bridge provided a unique opportunity to evaluate field installation issues and to examine the long-term performance of each system under identical traffic and environmental conditions. Using controlled truckload tests, the response of the bridge before retrofitting, shortly after retrofitting, and after one year of service was measured. The stiffness of the FRP systems was small in comparison to the stiffness of the bridge deck, and accordingly the measured deflections did not change noticeably after retrofitting. The measured strains suggest participation of the FRP systems, and more importantly, the strength of the retrofitted bridge was increased. A detailed 3D finite-element model of the original and retrofitted bridge was developed and calibrated based on the measured deflections. The model was used to predict more accurately the demands for computing the rating factors. The addition of FRP plates and fabrics led to a 22% increase in the rating factor and corresponding load limits. During a one-year period, traffic loading and environmental exposure did not apparently affect the performance of the FRP systems. The increased capacity and acceptable performance of the FRP systems enabled the engineers to remove the load limits in order to resume normal traffic. Future tests are necessary to monitor the long-term behavior of the FRP systems.
    • Download: (766.3Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Retrofit of a Three-Span Slab Bridge with Fiber Reinforced Polymer Systems—Testing and Rating

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/54236
    Collections
    • Journal of Composites for Construction

    Show full item record

    contributor authorBahram M. Shahrooz
    contributor authorSerpil Boy
    date accessioned2017-05-08T21:30:38Z
    date available2017-05-08T21:30:38Z
    date copyrightJune 2004
    date issued2004
    identifier other%28asce%291090-0268%282004%298%3A3%28241%29.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/54236
    description abstractA 45-year old, three-span reinforced concrete slab bridge with insufficient capacity was retrofitted with 76.2- and 127-mm wide bonded carbon fiber-reinforced polymer (FRP) plates, 102-mm wide bonded carbon FRP plates with mechanical anchors at the ends, and bonded carbon FRP fabrics. The use of four systems in one bridge provided a unique opportunity to evaluate field installation issues and to examine the long-term performance of each system under identical traffic and environmental conditions. Using controlled truckload tests, the response of the bridge before retrofitting, shortly after retrofitting, and after one year of service was measured. The stiffness of the FRP systems was small in comparison to the stiffness of the bridge deck, and accordingly the measured deflections did not change noticeably after retrofitting. The measured strains suggest participation of the FRP systems, and more importantly, the strength of the retrofitted bridge was increased. A detailed 3D finite-element model of the original and retrofitted bridge was developed and calibrated based on the measured deflections. The model was used to predict more accurately the demands for computing the rating factors. The addition of FRP plates and fabrics led to a 22% increase in the rating factor and corresponding load limits. During a one-year period, traffic loading and environmental exposure did not apparently affect the performance of the FRP systems. The increased capacity and acceptable performance of the FRP systems enabled the engineers to remove the load limits in order to resume normal traffic. Future tests are necessary to monitor the long-term behavior of the FRP systems.
    publisherAmerican Society of Civil Engineers
    titleRetrofit of a Three-Span Slab Bridge with Fiber Reinforced Polymer Systems—Testing and Rating
    typeJournal Paper
    journal volume8
    journal issue3
    journal titleJournal of Composites for Construction
    identifier doi10.1061/(ASCE)1090-0268(2004)8:3(241)
    treeJournal of Composites for Construction:;2004:;Volume ( 008 ):;issue: 003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian