Flexural Behavior and Deformability of Fiber Reinforced Polymer Prestressed Concrete BeamsSource: Journal of Composites for Construction:;2003:;Volume ( 007 ):;issue: 004Author:Patrick X. W. Zou
DOI: 10.1061/(ASCE)1090-0268(2003)7:4(275)Publisher: American Society of Civil Engineers
Abstract: After a brief review of the ductility and deformability indices currently used in the design of concrete beams reinforced or prestressed with steel or fiber reinforced polymer (FRP) tendons, a new definition of a deformability index (factor) for prestressed concrete beams is proposed. The new factor is defined in terms of both a deflection factor and a strength factor. The deflection factor is the ratio of the deflection at failure to the deflection at first cracking, while the strength factor is the ratio of the ultimate moment (or load) to the cracking moment (or load). The proposed deformability factor is verified not only by test results obtained by the writer, but also by other test results available in the literature and it appears to be a suitable measurement of the deformability of concrete beams prestressed with either FRP tendons or steel tendons.
|
Collections
Show full item record
contributor author | Patrick X. W. Zou | |
date accessioned | 2017-05-08T21:30:34Z | |
date available | 2017-05-08T21:30:34Z | |
date copyright | November 2003 | |
date issued | 2003 | |
identifier other | %28asce%291090-0268%282003%297%3A4%28275%29.pdf | |
identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/54195 | |
description abstract | After a brief review of the ductility and deformability indices currently used in the design of concrete beams reinforced or prestressed with steel or fiber reinforced polymer (FRP) tendons, a new definition of a deformability index (factor) for prestressed concrete beams is proposed. The new factor is defined in terms of both a deflection factor and a strength factor. The deflection factor is the ratio of the deflection at failure to the deflection at first cracking, while the strength factor is the ratio of the ultimate moment (or load) to the cracking moment (or load). The proposed deformability factor is verified not only by test results obtained by the writer, but also by other test results available in the literature and it appears to be a suitable measurement of the deformability of concrete beams prestressed with either FRP tendons or steel tendons. | |
publisher | American Society of Civil Engineers | |
title | Flexural Behavior and Deformability of Fiber Reinforced Polymer Prestressed Concrete Beams | |
type | Journal Paper | |
journal volume | 7 | |
journal issue | 4 | |
journal title | Journal of Composites for Construction | |
identifier doi | 10.1061/(ASCE)1090-0268(2003)7:4(275) | |
tree | Journal of Composites for Construction:;2003:;Volume ( 007 ):;issue: 004 | |
contenttype | Fulltext |