YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASCE
    • Journal of Composites for Construction
    • View Item
    •   YE&T Library
    • ASCE
    • Journal of Composites for Construction
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Polypropylene FRC Bridge Deck Slabs Transversely Prestressed with CFRP Tendons

    Source: Journal of Composites for Construction:;1998:;Volume ( 002 ):;issue: 004
    Author:
    Abass Braimah
    ,
    Mark F. Green
    ,
    Khaled A. Soudki
    DOI: 10.1061/(ASCE)1090-0268(1998)2:4(149)
    Publisher: American Society of Civil Engineers
    Abstract: Compressive membrane action in bridge deck slabs has been shown to considerably increase the failure loads of such slabs. Thus, the reinforcing requirement can be reduced if a system is configured to ensure development of compressive membrane action. Recent research has shown that the use of transverse prestressing in bridge deck slabs can achieve even greater savings by reducing slab thickness and reinforcing requirements while enhancing serviceability. This paper describes an investigation of a deck slab system totally devoid of steel reinforcement. A one-quarter-scale model of a typical deck slab supported on three steel girders was constructed in the laboratory and transversely prestressed with carbon-fiber-reinforced plastic tendons. Polypropylene-fiber-reinforced concrete was used for temperature and shrinkage crack control. The deck slab panels in the model bridge were tested to failure under simulated concentrated wheel loads. The observed failure mode of all panels was that of punching shear, at loads in excess of the scaled Ontario Highway Bridge Design Code specified design service load. Load-deflection curves and failure loads are presented and compared. The test results show that transverse prestressing enhances, considerably, the punching failure loads of deck slabs. It was also observed that bridge deck slabs totally devoid of any steel reinforcement perform satisfactorily in both strength and deformation.
    • Download: (1.589Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Polypropylene FRC Bridge Deck Slabs Transversely Prestressed with CFRP Tendons

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/54010
    Collections
    • Journal of Composites for Construction

    Show full item record

    contributor authorAbass Braimah
    contributor authorMark F. Green
    contributor authorKhaled A. Soudki
    date accessioned2017-05-08T21:30:18Z
    date available2017-05-08T21:30:18Z
    date copyrightNovember 1998
    date issued1998
    identifier other%28asce%291090-0268%281998%292%3A4%28149%29.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/54010
    description abstractCompressive membrane action in bridge deck slabs has been shown to considerably increase the failure loads of such slabs. Thus, the reinforcing requirement can be reduced if a system is configured to ensure development of compressive membrane action. Recent research has shown that the use of transverse prestressing in bridge deck slabs can achieve even greater savings by reducing slab thickness and reinforcing requirements while enhancing serviceability. This paper describes an investigation of a deck slab system totally devoid of steel reinforcement. A one-quarter-scale model of a typical deck slab supported on three steel girders was constructed in the laboratory and transversely prestressed with carbon-fiber-reinforced plastic tendons. Polypropylene-fiber-reinforced concrete was used for temperature and shrinkage crack control. The deck slab panels in the model bridge were tested to failure under simulated concentrated wheel loads. The observed failure mode of all panels was that of punching shear, at loads in excess of the scaled Ontario Highway Bridge Design Code specified design service load. Load-deflection curves and failure loads are presented and compared. The test results show that transverse prestressing enhances, considerably, the punching failure loads of deck slabs. It was also observed that bridge deck slabs totally devoid of any steel reinforcement perform satisfactorily in both strength and deformation.
    publisherAmerican Society of Civil Engineers
    titlePolypropylene FRC Bridge Deck Slabs Transversely Prestressed with CFRP Tendons
    typeJournal Paper
    journal volume2
    journal issue4
    journal titleJournal of Composites for Construction
    identifier doi10.1061/(ASCE)1090-0268(1998)2:4(149)
    treeJournal of Composites for Construction:;1998:;Volume ( 002 ):;issue: 004
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian