    Reduction of Indoor Radon by Air Cleaning—Case Study

    Source: Journal of Environmental Engineering:;2000:;Volume ( 126 ):;issue: 012
    Author:
    Scott A. Lowe
    ,
    Robert Pettenato
    DOI: 10.1061/(ASCE)0733-9372(2000)126:12(1125)
    Publisher: American Society of Civil Engineers
    Abstract: A field study was conducted over an intermittent period of 2.5 years to determine whether air cleaning, using a portable high efficiency particulate air filter air cleaner with an activated carbon filter, was a viable method of reducing indoor radon levels. Past studies showed that air cleaners could reduce radon and/or radon progeny concentrations. The data collected in this study showed that the air cleaner did not reduce radon levels and so was not an effective mitigation device. The data also showed that above radon levels of 6 pCi/L there was a strong positive linear correlation to moisture content. Below 6 pCi/L there was essentially no correlation. Radon concentrations were determined using EPA approved commercial test kits that were occasionally run in duplicate. In these cases it was found that there was good reproducibility between the test kits over a range of levels from 1.1 to 14.5 pCi/L, with the average difference being under 10%.
    • Download: (80.77Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Reduction of Indoor Radon by Air Cleaning—Case Study

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/53042
    Collections
    • Journal of Environmental Engineering

    Show full item record

    contributor authorScott A. Lowe
    contributor authorRobert Pettenato
    date accessioned2017-05-08T21:28:47Z
    date available2017-05-08T21:28:47Z
    date copyrightDecember 2000
    date issued2000
    identifier other%28asce%290733-9372%282000%29126%3A12%281125%29.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/53042
    description abstractA field study was conducted over an intermittent period of 2.5 years to determine whether air cleaning, using a portable high efficiency particulate air filter air cleaner with an activated carbon filter, was a viable method of reducing indoor radon levels. Past studies showed that air cleaners could reduce radon and/or radon progeny concentrations. The data collected in this study showed that the air cleaner did not reduce radon levels and so was not an effective mitigation device. The data also showed that above radon levels of 6 pCi/L there was a strong positive linear correlation to moisture content. Below 6 pCi/L there was essentially no correlation. Radon concentrations were determined using EPA approved commercial test kits that were occasionally run in duplicate. In these cases it was found that there was good reproducibility between the test kits over a range of levels from 1.1 to 14.5 pCi/L, with the average difference being under 10%.
    publisherAmerican Society of Civil Engineers
    titleReduction of Indoor Radon by Air Cleaning—Case Study
    typeJournal Paper
    journal volume126
    journal issue12
    journal titleJournal of Environmental Engineering
    identifier doi10.1061/(ASCE)0733-9372(2000)126:12(1125)
    treeJournal of Environmental Engineering:;2000:;Volume ( 126 ):;issue: 012
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian