    Archive

    Seismic Retrofit of State Street Bridge on Interstate 80

    Source: Journal of Bridge Engineering:;2004:;Volume ( 009 ):;issue: 004
    Author:
    Chris P. Pantelides
    ,
    Fadel Alameddine
    ,
    Tom Sardo
    ,
    Roy Imbsen
    DOI: 10.1061/(ASCE)1084-0702(2004)9:4(333)
    Publisher: American Society of Civil Engineers
    Abstract: The State Street Bridge, in Salt Lake City, was designed and built in 1965 according to the 1961 AASHO specifications; the design did not include earthquake-induced forces or displacements since only wind loads were considered. The bridge consists of four reinforced concrete (RC) bents supporting composite welded steel girders; the bents are supported on cast-in-place concrete piles and pile caps. A vulnerability analysis of the bridge was conducted that determined deficiencies in (1) confinement of column lap splice regions, (2) anchorage of longitudinal column bars in the bent cap, (3) confinement of column plastic hinge zones, and (4) shear capacity of columns and bent cap–column joints. Seismic retrofit designs using carbon-fiber-reinforced-polymer (CFRP) composites and steel jackets were performed and compared for three design spectra, including the 10% probability of exceedance in 250 years earthquake. The CFRP composite design was selected for implementation and application of the composite was carried out in the summer of 2000 and 2001, while the bridge was in service. The paper describes the CFRP composite design, which, in addition to column jackets, implemented an “ankle wrap” for improving joint shear strength and a “U-strap” for improving anchorage of column bars in the bent cap; other retrofit measures were implemented, such as bumper brackets and a deck slab retrofit. A capacity versus demand evaluation of the as-built and retrofitted bents is presented.
    • Download: (397.9Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Seismic Retrofit of State Street Bridge on Interstate 80

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/50754
    Collections
    • Journal of Bridge Engineering

    Show full item record

    contributor authorChris P. Pantelides
    contributor authorFadel Alameddine
    contributor authorTom Sardo
    contributor authorRoy Imbsen
    date accessioned2017-05-08T21:25:12Z
    date available2017-05-08T21:25:12Z
    date copyrightJuly 2004
    date issued2004
    identifier other%28asce%291084-0702%282004%299%3A4%28333%29.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/50754
    description abstractThe State Street Bridge, in Salt Lake City, was designed and built in 1965 according to the 1961 AASHO specifications; the design did not include earthquake-induced forces or displacements since only wind loads were considered. The bridge consists of four reinforced concrete (RC) bents supporting composite welded steel girders; the bents are supported on cast-in-place concrete piles and pile caps. A vulnerability analysis of the bridge was conducted that determined deficiencies in (1) confinement of column lap splice regions, (2) anchorage of longitudinal column bars in the bent cap, (3) confinement of column plastic hinge zones, and (4) shear capacity of columns and bent cap–column joints. Seismic retrofit designs using carbon-fiber-reinforced-polymer (CFRP) composites and steel jackets were performed and compared for three design spectra, including the 10% probability of exceedance in 250 years earthquake. The CFRP composite design was selected for implementation and application of the composite was carried out in the summer of 2000 and 2001, while the bridge was in service. The paper describes the CFRP composite design, which, in addition to column jackets, implemented an “ankle wrap” for improving joint shear strength and a “U-strap” for improving anchorage of column bars in the bent cap; other retrofit measures were implemented, such as bumper brackets and a deck slab retrofit. A capacity versus demand evaluation of the as-built and retrofitted bents is presented.
    publisherAmerican Society of Civil Engineers
    titleSeismic Retrofit of State Street Bridge on Interstate 80
    typeJournal Paper
    journal volume9
    journal issue4
    journal titleJournal of Bridge Engineering
    identifier doi10.1061/(ASCE)1084-0702(2004)9:4(333)
    treeJournal of Bridge Engineering:;2004:;Volume ( 009 ):;issue: 004
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace