    Archive

    Simulated Field Testing of High Performance Grouts for Post-Tensioning

    Source: Journal of Bridge Engineering:;2002:;Volume ( 007 ):;issue: 002
    Author:
    A. J. Schokker
    ,
    John E. Breen
    ,
    M. E. Kreger
    DOI: 10.1061/(ASCE)1084-0702(2002)7:2(127)
    Publisher: American Society of Civil Engineers
    Abstract: A series of fresh property tests and accelerated corrosion tests were used to develop grouts that combine favorable grouting properties with good corrosion protection. The grouts were then pumped into a clear duct with multiple drapes to observe their behavior under simulated field conditions. Two high performance grouts for post-tensioning applications are recommended from this testing. For horizontal applications, a low water-cement ratio grout with fly ash (Class C) is recommended. For vertical applications (such as tall bridge piers), a low water-cement ratio grout containing antibleed admixture is recommended.
    • Download: (841.4Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Simulated Field Testing of High Performance Grouts for Post-Tensioning

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/50614
    Collections
    • Journal of Bridge Engineering

    Show full item record

    contributor authorA. J. Schokker
    contributor authorJohn E. Breen
    contributor authorM. E. Kreger
    date accessioned2017-05-08T21:25:00Z
    date available2017-05-08T21:25:00Z
    date copyrightMarch 2002
    date issued2002
    identifier other%28asce%291084-0702%282002%297%3A2%28127%29.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/50614
    description abstractA series of fresh property tests and accelerated corrosion tests were used to develop grouts that combine favorable grouting properties with good corrosion protection. The grouts were then pumped into a clear duct with multiple drapes to observe their behavior under simulated field conditions. Two high performance grouts for post-tensioning applications are recommended from this testing. For horizontal applications, a low water-cement ratio grout with fly ash (Class C) is recommended. For vertical applications (such as tall bridge piers), a low water-cement ratio grout containing antibleed admixture is recommended.
    publisherAmerican Society of Civil Engineers
    titleSimulated Field Testing of High Performance Grouts for Post-Tensioning
    typeJournal Paper
    journal volume7
    journal issue2
    journal titleJournal of Bridge Engineering
    identifier doi10.1061/(ASCE)1084-0702(2002)7:2(127)
    treeJournal of Bridge Engineering:;2002:;Volume ( 007 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian