    Design Method of a Hanger System for Long-Span Suspension Bridge

    Source: Journal of Bridge Engineering:;2001:;Volume ( 006 ):;issue: 003
    Author:
    Munenobu Kondoh
    ,
    Motoi Okuda
    ,
    Kouji Kawaguchi
    ,
    Takefumi Yamazaki
    DOI: 10.1061/(ASCE)1084-0702(2001)6:3(176)
    Publisher: American Society of Civil Engineers
    Abstract: A parallel wire strand (PWS) rope instead of a strand rope of the center fit rope core type was used as the hanger rope in the world's longest suspension bridge, the Akashi Kaikyo Bridge, one of the Honshu-Shikoku Bridges in Japan. The strand ropes of the center fit rope core type are inconvenient and uneconomical to maintain as 100–200 m-long hanger ropes. This paper presents the design method for the PWS hanger system in long-span suspension bridges. The structural characteristics, structural analysis, stress calculation, and the examination of fatigue against random wind load of the PWS hanger system were also investigated.
    • Download: (192.1Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Design Method of a Hanger System for Long-Span Suspension Bridge

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/50539
    Collections
    • Journal of Bridge Engineering

    Show full item record

    contributor authorMunenobu Kondoh
    contributor authorMotoi Okuda
    contributor authorKouji Kawaguchi
    contributor authorTakefumi Yamazaki
    date accessioned2017-05-08T21:24:53Z
    date available2017-05-08T21:24:53Z
    date copyrightJune 2001
    date issued2001
    identifier other%28asce%291084-0702%282001%296%3A3%28176%29.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/50539
    description abstractA parallel wire strand (PWS) rope instead of a strand rope of the center fit rope core type was used as the hanger rope in the world's longest suspension bridge, the Akashi Kaikyo Bridge, one of the Honshu-Shikoku Bridges in Japan. The strand ropes of the center fit rope core type are inconvenient and uneconomical to maintain as 100–200 m-long hanger ropes. This paper presents the design method for the PWS hanger system in long-span suspension bridges. The structural characteristics, structural analysis, stress calculation, and the examination of fatigue against random wind load of the PWS hanger system were also investigated.
    publisherAmerican Society of Civil Engineers
    titleDesign Method of a Hanger System for Long-Span Suspension Bridge
    typeJournal Paper
    journal volume6
    journal issue3
    journal titleJournal of Bridge Engineering
    identifier doi10.1061/(ASCE)1084-0702(2001)6:3(176)
    treeJournal of Bridge Engineering:;2001:;Volume ( 006 ):;issue: 003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian