    Relaxation in High-Strength Bolted Connections Using Galvanized Steel

    Source: Journal of Bridge Engineering:;2000:;Volume ( 005 ):;issue: 002
    Author:
    Jun Yang
    ,
    John T. DeWolf
    DOI: 10.1061/(ASCE)1084-0702(2000)5:2(99)
    Publisher: American Society of Civil Engineers
    Abstract: In recent bridge construction in Connecticut involving heavy sections, galvanized coating thicknesses were in excess of 12 mils. The current American Association of State Highway and Transportation Officials specification is based on research conducted with coating thicknesses not greater than 6 mils. Since thicker coatings on steel can reduce shear capacity in high-strength bolted connections, there was concern that the thick galvanized coating could compromise the performance. In this research, tests were conducted to study the relaxation and the shear capacity of high-strength bolted connections with galvanized coating thicknesses up to 20 mils. Both normal and oversize holes were studied. The research shows that the shear capacity of connections with thick galvanized coatings is reduced due to the loss in the clamping force. The test results have been used to develop design guidelines.
    • Download: (127.4Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Relaxation in High-Strength Bolted Connections Using Galvanized Steel

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/50489
    Collections
    • Journal of Bridge Engineering

    Show full item record

    contributor authorJun Yang
    contributor authorJohn T. DeWolf
    date accessioned2017-05-08T21:24:47Z
    date available2017-05-08T21:24:47Z
    date copyrightMay 2000
    date issued2000
    identifier other%28asce%291084-0702%282000%295%3A2%2899%29.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/50489
    description abstractIn recent bridge construction in Connecticut involving heavy sections, galvanized coating thicknesses were in excess of 12 mils. The current American Association of State Highway and Transportation Officials specification is based on research conducted with coating thicknesses not greater than 6 mils. Since thicker coatings on steel can reduce shear capacity in high-strength bolted connections, there was concern that the thick galvanized coating could compromise the performance. In this research, tests were conducted to study the relaxation and the shear capacity of high-strength bolted connections with galvanized coating thicknesses up to 20 mils. Both normal and oversize holes were studied. The research shows that the shear capacity of connections with thick galvanized coatings is reduced due to the loss in the clamping force. The test results have been used to develop design guidelines.
    publisherAmerican Society of Civil Engineers
    titleRelaxation in High-Strength Bolted Connections Using Galvanized Steel
    typeJournal Paper
    journal volume5
    journal issue2
    journal titleJournal of Bridge Engineering
    identifier doi10.1061/(ASCE)1084-0702(2000)5:2(99)
    treeJournal of Bridge Engineering:;2000:;Volume ( 005 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian