| contributor author | C. L. Hanson | |
| contributor author | M. D. Burgess | |
| date accessioned | 2017-05-08T21:23:05Z | |
| date available | 2017-05-08T21:23:05Z | |
| date copyright | January 1997 | |
| date issued | 1997 | |
| identifier other | %28asce%291084-0699%281997%292%3A1%2837%29.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/49363 | |
| description abstract | Recently developed integrated circuit technology and new reliable pressure transducers have made it possible to develop a battery-operated system to automatically fill class A evaporation pans from stored water. The system records and stores the average of 12 pan level records during a 1 min time period at the end of each 15 min period for later transmission to a central data storage facility. The measurement sensitivity of the system is 0.02 cm of evaporation over a range of 3.5 cm. A field calibration of the system showed that there was a very good ( | |
| publisher | American Society of Civil Engineers | |
| title | Time‐ and Level‐Controlled Filling System for Class A Evaporation Pans | |
| type | Journal Paper | |
| journal volume | 2 | |
| journal issue | 1 | |
| journal title | Journal of Hydrologic Engineering | |
| identifier doi | 10.1061/(ASCE)1084-0699(1997)2:1(37) | |
| tree | Journal of Hydrologic Engineering:;1997:;Volume ( 002 ):;issue: 001 | |
| contenttype | Fulltext | |