    Cutoff Frequencies for Impulse Response Tests of Existing Foundations

    Source: Journal of Performance of Constructed Facilities:;2000:;Volume ( 014 ):;issue: 001
    Author:
    Sarah L. Gassman
    ,
    Richard J. Finno
    DOI: 10.1061/(ASCE)0887-3828(2000)14:1(11)
    Publisher: American Society of Civil Engineers
    Abstract: The impulse response test is a nondestructive evaluation technique commonly used for quality control of driven concrete piles and drilled shafts where the pile heads are accessible. When evaluating existing foundations, the presence of a pile cap or other structure makes the pile heads inaccessible and introduces uncertainties in the interpretation of impulse response results. A test section was constructed at the National Geotechnical Experimentation Site (NGES) at Northwestern University to examine the applicability of nondestructive testing methods in evaluating deep foundations under inaccessible-head conditions. This paper focuses on the results of impulse response tests conducted atop the three pile caps at the NGES. Based on field experimentation and numerical simulations, a frequency was determined below which the impulse response test could be used for inaccessible-head conditions. This cutoff frequency primarily depends upon the geometry of the pile cap and pile. A case study is presented that describes impulse response tests obtained on a number of drilled shafts both after the shaft was constructed and after grade beams and walls were built. The results of these tests also follow the trends observed in the NGES tests related to cutoff frequency.
    • Download: (195.3Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Cutoff Frequencies for Impulse Response Tests of Existing Foundations

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/44203
    Collections
    • Journal of Performance of Constructed Facilities

    Show full item record

    contributor authorSarah L. Gassman
    contributor authorRichard J. Finno
    date accessioned2017-05-08T21:14:53Z
    date available2017-05-08T21:14:53Z
    date copyrightFebruary 2000
    date issued2000
    identifier other%28asce%290887-3828%282000%2914%3A1%2811%29.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/44203
    description abstractThe impulse response test is a nondestructive evaluation technique commonly used for quality control of driven concrete piles and drilled shafts where the pile heads are accessible. When evaluating existing foundations, the presence of a pile cap or other structure makes the pile heads inaccessible and introduces uncertainties in the interpretation of impulse response results. A test section was constructed at the National Geotechnical Experimentation Site (NGES) at Northwestern University to examine the applicability of nondestructive testing methods in evaluating deep foundations under inaccessible-head conditions. This paper focuses on the results of impulse response tests conducted atop the three pile caps at the NGES. Based on field experimentation and numerical simulations, a frequency was determined below which the impulse response test could be used for inaccessible-head conditions. This cutoff frequency primarily depends upon the geometry of the pile cap and pile. A case study is presented that describes impulse response tests obtained on a number of drilled shafts both after the shaft was constructed and after grade beams and walls were built. The results of these tests also follow the trends observed in the NGES tests related to cutoff frequency.
    publisherAmerican Society of Civil Engineers
    titleCutoff Frequencies for Impulse Response Tests of Existing Foundations
    typeJournal Paper
    journal volume14
    journal issue1
    journal titleJournal of Performance of Constructed Facilities
    identifier doi10.1061/(ASCE)0887-3828(2000)14:1(11)
    treeJournal of Performance of Constructed Facilities:;2000:;Volume ( 014 ):;issue: 001
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian