    Evaluation of L'Ambiance Plaza Posttensioned Floor Slabs

    Source: Journal of Performance of Constructed Facilities:;1991:;Volume ( 005 ):;issue: 002
    Author:
    Randall W. Poston
    ,
    Gerard C. Feldmann
    ,
    Mario G. Suarez
    DOI: 10.1061/(ASCE)0887-3828(1991)5:2(75)
    Publisher: American Society of Civil Engineers
    Abstract: This paper summarizes a structural evaluation of the posttensioned floor lift slabs of L'Ambiance Plaza, Bridgeport, Connecticut. The evaluation has been conducted to investigate, among other factors, the effect on slab stresses of the unorthodox horizontal splay of posttensioned tendons around column 4.8E and the effect of shear wall openings that existed during the lifting operation, for ideal lifting conditions (slab perfectly level), and for scenarios less than ideal. Initially, hand computations are made using simplified beam models to examine two areas of the west‐tower slab design that appeared particularly suspicious. Those computations reveal that a more refined stress analysis is warranted. To investigate the slab stresses more precisely, linear elastic finite element analyses of a typical west‐tower floor slab are conducted. Results from the analyses indicate that the anomalous layout of the posttensioning tendons in the west tower could be considered a possible cause that triggered the failure or, at a minimum, was clearly a factor in the propagation of the collapse after it had begun. The inclusion of nominal amounts of auxiliary bonded mild reinforcement (structural integrity steel) in the bottom of the slabs, continuous through the column strips, might have confined the slab failure, assuming the column supports and jacks could sustain the redistributed load.
    • Download: (983.7Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Evaluation of L'Ambiance Plaza Posttensioned Floor Slabs

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/43936
    Collections
    • Journal of Performance of Constructed Facilities

    Show full item record

    contributor authorRandall W. Poston
    contributor authorGerard C. Feldmann
    contributor authorMario G. Suarez
    date accessioned2017-05-08T21:14:24Z
    date available2017-05-08T21:14:24Z
    date copyrightMay 1991
    date issued1991
    identifier other%28asce%290887-3828%281991%295%3A2%2875%29.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/43936
    description abstractThis paper summarizes a structural evaluation of the posttensioned floor lift slabs of L'Ambiance Plaza, Bridgeport, Connecticut. The evaluation has been conducted to investigate, among other factors, the effect on slab stresses of the unorthodox horizontal splay of posttensioned tendons around column 4.8E and the effect of shear wall openings that existed during the lifting operation, for ideal lifting conditions (slab perfectly level), and for scenarios less than ideal. Initially, hand computations are made using simplified beam models to examine two areas of the west‐tower slab design that appeared particularly suspicious. Those computations reveal that a more refined stress analysis is warranted. To investigate the slab stresses more precisely, linear elastic finite element analyses of a typical west‐tower floor slab are conducted. Results from the analyses indicate that the anomalous layout of the posttensioning tendons in the west tower could be considered a possible cause that triggered the failure or, at a minimum, was clearly a factor in the propagation of the collapse after it had begun. The inclusion of nominal amounts of auxiliary bonded mild reinforcement (structural integrity steel) in the bottom of the slabs, continuous through the column strips, might have confined the slab failure, assuming the column supports and jacks could sustain the redistributed load.
    publisherAmerican Society of Civil Engineers
    titleEvaluation of L'Ambiance Plaza Posttensioned Floor Slabs
    typeJournal Paper
    journal volume5
    journal issue2
    journal titleJournal of Performance of Constructed Facilities
    identifier doi10.1061/(ASCE)0887-3828(1991)5:2(75)
    treeJournal of Performance of Constructed Facilities:;1991:;Volume ( 005 ):;issue: 002
    contenttypeFulltext