    Roof Collapse, Magic Mart Store, Bolivar, Tennessee

    Source: Journal of Performance of Constructed Facilities:;1987:;Volume ( 001 ):;issue: 002
    Author:
    Glenn R. Bell
    ,
    James C. Parker
    DOI: 10.1061/(ASCE)0887-3828(1987)1:2(63)
    Publisher: American Society of Civil Engineers
    Abstract: This paper summarizes an investigation of the July 2, 1983, roof collapse of the Magic Mart store in Bolivar, Tennessee. The building was a onestory retail store of steel‐framed roof construction. The collapse occurred during a severe thunderstorm with intense rainfall. The investigation includes review of background information and eyewitness accounts of the collapse, review of design and construction documents, site investigation and sample collection, laboratory testing of samples of the collapse debris, and structural analyses. The initiating mode of failure was instability of one of the beam‐column connections of the roof framing, triggered by ponded roof water. The principal cause of the failure was inadequate buckling resistance of the unbraced and unstiffened beam‐column connections, due to major deviations in the construction from the design documents. Also contributing to the failure were ponding rain water caused by improper slope and drainage of the roof and the increased weight of roofing materials added during the 10‐year life of the building. The paper concludes with a summary of the results of a personal injury law suit resulting from the collapse, and with recommendations for improvement in design and construction practices based on the lessons learned from this failure.
    • Download: (1.318Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Roof Collapse, Magic Mart Store, Bolivar, Tennessee

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/43824
    Collections
    • Journal of Performance of Constructed Facilities

    Show full item record

    contributor authorGlenn R. Bell
    contributor authorJames C. Parker
    date accessioned2017-05-08T21:14:12Z
    date available2017-05-08T21:14:12Z
    date copyrightMay 1987
    date issued1987
    identifier other%28asce%290887-3828%281987%291%3A2%2863%29.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/43824
    description abstractThis paper summarizes an investigation of the July 2, 1983, roof collapse of the Magic Mart store in Bolivar, Tennessee. The building was a onestory retail store of steel‐framed roof construction. The collapse occurred during a severe thunderstorm with intense rainfall. The investigation includes review of background information and eyewitness accounts of the collapse, review of design and construction documents, site investigation and sample collection, laboratory testing of samples of the collapse debris, and structural analyses. The initiating mode of failure was instability of one of the beam‐column connections of the roof framing, triggered by ponded roof water. The principal cause of the failure was inadequate buckling resistance of the unbraced and unstiffened beam‐column connections, due to major deviations in the construction from the design documents. Also contributing to the failure were ponding rain water caused by improper slope and drainage of the roof and the increased weight of roofing materials added during the 10‐year life of the building. The paper concludes with a summary of the results of a personal injury law suit resulting from the collapse, and with recommendations for improvement in design and construction practices based on the lessons learned from this failure.
    publisherAmerican Society of Civil Engineers
    titleRoof Collapse, Magic Mart Store, Bolivar, Tennessee
    typeJournal Paper
    journal volume1
    journal issue2
    journal titleJournal of Performance of Constructed Facilities
    identifier doi10.1061/(ASCE)0887-3828(1987)1:2(63)
    treeJournal of Performance of Constructed Facilities:;1987:;Volume ( 001 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian