    Archive

    Reliability of Domestic-Waste Biofilm Reactors

    Source: Journal of Environmental Engineering:;1995:;Volume ( 121 ):;issue: 011
    Author:
    S. T. Quek
    ,
    K. K. Ang
    ,
    S. L. Ong
    ,
    J. G. Tan
    DOI: 10.1061/(ASCE)0733-9372(1995)121:11(785)
    Publisher: American Society of Civil Engineers
    Abstract: The effect of uncertainty in the system parameters on the reliability of domestic-waste biofilm reactors is investigated. Based on typical ranges and default values reported in published literature, a representative set of statistics describing the uncertainty in the parameters is selected for this study. Monte Carlo simulation runs are performed, from which the variability in the reactor height required to meet a specified effluent concentration level is estimated. The parameters contributing significantly to this variability are also established. From the results, a preliminary set of factors corresponding to various performance reliability levels is proposed by which the reactor height from deterministic analysis should be multiplied to arrive at the design reactor height. A similar set of partial factors that one can use to factor the values of the system parameters prior to the deterministic analysis to compute the reactor height is also proposed as an alternative means of accounting for the effect of uncertainty. From an operational point of view, the variability in the effluent quality resulting from the uncertainty in the system parameters is also investigated for a reactor with a fixed height.
    • Download: (897.6Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Reliability of Domestic-Waste Biofilm Reactors

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/43409
    Collections
    • Journal of Environmental Engineering

    Show full item record

    contributor authorS. T. Quek
    contributor authorK. K. Ang
    contributor authorS. L. Ong
    contributor authorJ. G. Tan
    date accessioned2017-05-08T21:13:32Z
    date available2017-05-08T21:13:32Z
    date copyrightNovember 1995
    date issued1995
    identifier other%28asce%290733-9372%281995%29121%3A11%28785%29.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/43409
    description abstractThe effect of uncertainty in the system parameters on the reliability of domestic-waste biofilm reactors is investigated. Based on typical ranges and default values reported in published literature, a representative set of statistics describing the uncertainty in the parameters is selected for this study. Monte Carlo simulation runs are performed, from which the variability in the reactor height required to meet a specified effluent concentration level is estimated. The parameters contributing significantly to this variability are also established. From the results, a preliminary set of factors corresponding to various performance reliability levels is proposed by which the reactor height from deterministic analysis should be multiplied to arrive at the design reactor height. A similar set of partial factors that one can use to factor the values of the system parameters prior to the deterministic analysis to compute the reactor height is also proposed as an alternative means of accounting for the effect of uncertainty. From an operational point of view, the variability in the effluent quality resulting from the uncertainty in the system parameters is also investigated for a reactor with a fixed height.
    publisherAmerican Society of Civil Engineers
    titleReliability of Domestic-Waste Biofilm Reactors
    typeJournal Paper
    journal volume121
    journal issue11
    journal titleJournal of Environmental Engineering
    identifier doi10.1061/(ASCE)0733-9372(1995)121:11(785)
    treeJournal of Environmental Engineering:;1995:;Volume ( 121 ):;issue: 011
    contenttypeFulltext