    Seismic Bearing Capacity of Strip Foundations Placed on Stable Slopes of Homogeneously Fractured Rock Mass

    Source: International Journal of Geomechanics:;2025:;Volume ( 025 ):;issue: 001::page 04024308-1
    Author:
    Shikhar Prakash
    ,
    Yogendra Singh
    ,
    Rajinder Bhasin
    DOI: 10.1061/IJGNAI.GMENG-9917
    Publisher: American Society of Civil Engineers
    Abstract: Strip foundations are the most prevalently used shallow foundations in low-rise residential buildings in hilly regions. The strip foundations in many of these structures are often placed on rock slopes. In a seismic event, the behavior of the foundation–rock slope system is complex. It is characterized by a reduced bearing capacity in the strip foundation for low-intensity shaking and rock slope instability at higher seismic intensity. The quantification of this behavior is essential for the seismic design of these foundations. This work presents an analytical formulation to estimate the critical seismic loading for a given geometry and material properties of a rock slope that is represented by the Hoek–Brown (HB) failure criterion, up to which the stability of the slope is ensured. An extensive study that uses pseudo-static finite-element limit analysis (FELA) is carried out to parametrically analyze the effect of the slope angle and seismic acceleration on the seismic bearing capacity factor of a footing on rock slopes with a wide range of rock mass properties. The results of the FELA are utilized to develop a design tool (Rock-Bearing) to estimate the bearing capacity of strip foundations that are placed on rock slopes. The developed tool could be used instead of the computationally expensive numerical analysis for the preliminary design of foundations in seismically active hilly areas. The assessment of the seismic bearing capacity of a geomaterial that sustains a strip foundation is a crucial element in the design of strip foundations that rest on it. Using the code-based presumptive values for the bearing capacity for the seismic design might lead to unsafe designs where the strip foundation is near the edge of a slope in hilly areas. The seismic design of these foundations demands a comprehensive analysis, which preliminarily investigates the global stability of the slope and further incorporates the effect of horizontal seismic acceleration and vicinity of the slope in the reduction of the bearing capacity. The previously illustrated design requirements demand a sophisticated analysis of the design. This work develops a design aid tool that could be used instead of the computationally expensive numerical analysis for the preliminary design of foundations in seismically active hilly areas.
    • Download: (1.393Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Seismic Bearing Capacity of Strip Foundations Placed on Stable Slopes of Homogeneously Fractured Rock Mass

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4309151
    Collections
    • International Journal of Geomechanics

    Show full item record

    contributor authorShikhar Prakash
    contributor authorYogendra Singh
    contributor authorRajinder Bhasin
    date accessioned2026-02-16T21:24:12Z
    date available2026-02-16T21:24:12Z
    date copyright2025/01/01
    date issued2025
    identifier otherIJGNAI.GMENG-9917.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4309151
    description abstractStrip foundations are the most prevalently used shallow foundations in low-rise residential buildings in hilly regions. The strip foundations in many of these structures are often placed on rock slopes. In a seismic event, the behavior of the foundation–rock slope system is complex. It is characterized by a reduced bearing capacity in the strip foundation for low-intensity shaking and rock slope instability at higher seismic intensity. The quantification of this behavior is essential for the seismic design of these foundations. This work presents an analytical formulation to estimate the critical seismic loading for a given geometry and material properties of a rock slope that is represented by the Hoek–Brown (HB) failure criterion, up to which the stability of the slope is ensured. An extensive study that uses pseudo-static finite-element limit analysis (FELA) is carried out to parametrically analyze the effect of the slope angle and seismic acceleration on the seismic bearing capacity factor of a footing on rock slopes with a wide range of rock mass properties. The results of the FELA are utilized to develop a design tool (Rock-Bearing) to estimate the bearing capacity of strip foundations that are placed on rock slopes. The developed tool could be used instead of the computationally expensive numerical analysis for the preliminary design of foundations in seismically active hilly areas. The assessment of the seismic bearing capacity of a geomaterial that sustains a strip foundation is a crucial element in the design of strip foundations that rest on it. Using the code-based presumptive values for the bearing capacity for the seismic design might lead to unsafe designs where the strip foundation is near the edge of a slope in hilly areas. The seismic design of these foundations demands a comprehensive analysis, which preliminarily investigates the global stability of the slope and further incorporates the effect of horizontal seismic acceleration and vicinity of the slope in the reduction of the bearing capacity. The previously illustrated design requirements demand a sophisticated analysis of the design. This work develops a design aid tool that could be used instead of the computationally expensive numerical analysis for the preliminary design of foundations in seismically active hilly areas.
    publisherAmerican Society of Civil Engineers
    titleSeismic Bearing Capacity of Strip Foundations Placed on Stable Slopes of Homogeneously Fractured Rock Mass
    typeJournal Article
    journal volume25
    journal issue1
    journal titleInternational Journal of Geomechanics
    identifier doi10.1061/IJGNAI.GMENG-9917
    journal fristpage04024308-1
    journal lastpage04024308-12
    page12
    treeInternational Journal of Geomechanics:;2025:;Volume ( 025 ):;issue: 001
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian