| contributor author | Manon, Bas-dit-Nugues | |
| contributor author | Ketani, Teddy | |
| contributor author | Bastard, Claire | |
| contributor author | Rosi, Giuseppe | |
| contributor author | Lomani, Hugues Albini | |
| contributor author | Flouzat-Lachaniette, Charles-Henri | |
| contributor author | Dubory, Arnaud | |
| contributor author | Haïat, Guillaume | |
| date accessioned | 2025-08-20T09:37:35Z | |
| date available | 2025-08-20T09:37:35Z | |
| date copyright | 5/5/2025 12:00:00 AM | |
| date issued | 2025 | |
| identifier issn | 0148-0731 | |
| identifier other | bio_147_06_064502.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl1/handle/yetl/4308581 | |
| description abstract | High tibial osteotomy is a common procedure for knee osteoarthritis during which the surgeon partially opens the tibia and must stop impacting when cortical bone is reached by the osteotome. Surgeons rely on their proprioception and fluoroscopy to conduct the surgery. Our group has developed an instrumented hammer to assess the mechanical properties of the material surrounding the osteotome tip. The aim of this ex vivo study is to determine whether this hammer can be used to detect the transition from cortical to trabecular bone and vice versa. Osteotomies were performed until rupture in pig tibia using the instrumented hammer. An algorithm was developed to detect both transitions based on the relative variation of an indicator derived from the time variation of the force. The detection by the algorithm of both transitions was compared with the position of the osteotome measured with a video camera and with surgeon proprioception. The difference between the detection of the video and the algorithm (respectively, the video and the surgeon; the surgeon and the algorithm) is 1.0±1.5 impacts (respectively, 0.5±0.6 impacts; 1.4±1.8 impacts), for the detection of the transition from the cortical to trabecular bone. For the transition from the trabecular to cortical bone, the difference is 3.6±2.6 impacts (respectively, 3.9±2.4 impacts; 0.8±0.9 impacts), and the detection by the algorithm was always done before the sample rupture. This ex vivo study demonstrates that this method could prevent impacts leading to hinge rupture. | |
| publisher | The American Society of Mechanical Engineers (ASME) | |
| title | An Instrumented Hammer to Detect the Bone Transitions During an High Tibial Osteotomy: An Animal Study | |
| type | Journal Paper | |
| journal volume | 147 | |
| journal issue | 6 | |
| journal title | Journal of Biomechanical Engineering | |
| identifier doi | 10.1115/1.4068372 | |
| journal fristpage | 64502-1 | |
| journal lastpage | 64502-8 | |
| page | 8 | |
| tree | Journal of Biomechanical Engineering:;2025:;volume( 147 ):;issue: 006 | |
| contenttype | Fulltext | |