    A Generic Design Approach for the Ultimate Shear Strength of the CFS Welded Moment Beam-to-Beam Connection

    Source: Journal of Structural Engineering:;2025:;Volume ( 151 ):;issue: 003::page 04025009-1
    Author:
    Ranjithkumar Palaniyammal Madheswaran
    ,
    Nagaraju Mallepogu
    ,
    Mahendrakumar Mathialagu Madhavan
    DOI: 10.1061/JSENDH.STENG-13605
    Publisher: American Society of Civil Engineers
    Abstract: This paper reports on the shear performance of a cold-formed steel (CFS) beam-to-beam moment welded moment connection with 28 laboratory tests. The tested moment connection comprises a welded CFS 90° clip angle (CA) and a flat-shaped CFS flange strip (FS) that connects the web and flange portions of the beam members. The observed failure modes in the tested samples, namely, (1) tearing failure; and (2) local buckling of the welded CA are classified based on the aspect ratio of the CA. A detailed parametric study was conducted on the ultimate shear strength of the welded moment connection for the variation in the thickness, width, and depth of the CA. The effect of the FS in improving the shear strength of the chosen welded moment connection over the welded shear connection was quantified, and design guidelines were suggested. Two design methods, namely, (1) empirical approach, which is specific only for the chosen moment connection, and (2) generic design approach, which applies to shear and moment connections, have been proposed. In this study, CFS welded moment connections are compared with CFS welded shear connections, and design recommendations are suggested.
    • Download: (5.104Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      A Generic Design Approach for the Ultimate Shear Strength of the CFS Welded Moment Beam-to-Beam Connection

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4306687
    Collections
    • Journal of Structural Engineering

    Show full item record

    contributor authorRanjithkumar Palaniyammal Madheswaran
    contributor authorNagaraju Mallepogu
    contributor authorMahendrakumar Mathialagu Madhavan
    date accessioned2025-08-17T22:16:05Z
    date available2025-08-17T22:16:05Z
    date copyright3/1/2025 12:00:00 AM
    date issued2025
    identifier otherJSENDH.STENG-13605.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4306687
    description abstractThis paper reports on the shear performance of a cold-formed steel (CFS) beam-to-beam moment welded moment connection with 28 laboratory tests. The tested moment connection comprises a welded CFS 90° clip angle (CA) and a flat-shaped CFS flange strip (FS) that connects the web and flange portions of the beam members. The observed failure modes in the tested samples, namely, (1) tearing failure; and (2) local buckling of the welded CA are classified based on the aspect ratio of the CA. A detailed parametric study was conducted on the ultimate shear strength of the welded moment connection for the variation in the thickness, width, and depth of the CA. The effect of the FS in improving the shear strength of the chosen welded moment connection over the welded shear connection was quantified, and design guidelines were suggested. Two design methods, namely, (1) empirical approach, which is specific only for the chosen moment connection, and (2) generic design approach, which applies to shear and moment connections, have been proposed. In this study, CFS welded moment connections are compared with CFS welded shear connections, and design recommendations are suggested.
    publisherAmerican Society of Civil Engineers
    titleA Generic Design Approach for the Ultimate Shear Strength of the CFS Welded Moment Beam-to-Beam Connection
    typeJournal Article
    journal volume151
    journal issue3
    journal titleJournal of Structural Engineering
    identifier doi10.1061/JSENDH.STENG-13605
    journal fristpage04025009-1
    journal lastpage04025009-18
    page18
    treeJournal of Structural Engineering:;2025:;Volume ( 151 ):;issue: 003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian