Show simple item record

contributor authorAlawneh, Yara
contributor authorZhou, James J.
contributor authorSewani, Alykhan
contributor authorDueck, Andrew
contributor authorTavallaei, M. Ali
date accessioned2025-04-21T10:15:06Z
date available2025-04-21T10:15:06Z
date copyright9/19/2024 12:00:00 AM
date issued2024
identifier issn1932-6181
identifier othermed_018_04_041004.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4305798
description abstractAbdominal aortic aneurysms (AAA) are often repaired through an endovascular approach known as endovascular aneurysm repair (EVAR). The success and duration of these challenging procedures are primarily attributable to the accuracy and reliability of navigating corresponding interventional devices. This study investigates the performance of conventional nonsteerable and steerable catheters in EVAR procedures, focusing on two primary metrics: reachable workspace and gate cannulation success. We developed two abdominal aortic aneurysm (AAA) phantoms using patient CT images for our experiments. Under X-ray fluoroscopy guidance, the reachable workspace was quantified, and gate cannulation success rates, cannulation time, and fluoroscopy times were recorded for both nonsteerable and steerable catheters and were compared. We were unable to observe statistically significant differences between the two catheter types in overall cannulation success rates or fluoroscopy time. However, in challenging anatomical scenarios (particularly a more challenging gate location), the steerable catheter showed statistically significant advantages in success rates and cannulation times. While there were no statistical differences in reachable workspace between nonsteerable and steerable catheters when considering the whole aneurysm, segmented analysis showed that the steerable catheter performed better in the central region, and nonsteerable catheters performed better in the peripheral region. This study provides a systematic method for quantifying the performance of endovascular devices. The findings suggest that while steerable catheters may offer advantages in complex anatomical conditions, nonsteerable catheters are preferable in peripheral areas of the aneurysm. These insights can inform catheter selection in EVAR, potentially influencing device design and clinical practice.
publisherThe American Society of Mechanical Engineers (ASME)
titleCharacterization of Conventional Endovascular Devices in Treatment of Abdominal Aortic Aneurysms
typeJournal Paper
journal volume18
journal issue4
journal titleJournal of Medical Devices
identifier doi10.1115/1.4066227
journal fristpage41004-1
journal lastpage41004-8
page8
treeJournal of Medical Devices:;2024:;volume( 018 ):;issue: 004
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record