YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASCE
    • Journal of Materials in Civil Engineering
    • View Item
    •   YE&T Library
    • ASCE
    • Journal of Materials in Civil Engineering
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Experimental Research on the Structural Performance of Shield Tunnel Segments Subjected to Different Fire Temperatures

    Source: Journal of Materials in Civil Engineering:;2024:;Volume ( 036 ):;issue: 012::page 04024411-1
    Author:
    Hongbin Chen
    ,
    Yujing Jiang
    ,
    Dongdong Pan
    ,
    Huibin Sun
    ,
    Qian Zhang
    ,
    Peng Yan
    DOI: 10.1061/JMCEE7.MTENG-17685
    Publisher: American Society of Civil Engineers
    Abstract: In order to determine the damaging effect of different fire temperatures on a segment, experimental research was carried out on the structural performance of segments subjected to different fire temperatures. A temperature plateau occurred when the temperature reached 100°C. There were two temperature layers across the 300 mm thickness of the segment due to heating on one side only, and the temperature gradient within 0–50 mm was much more significant than that within 50–300 mm. The concrete spalling and the cracking initiated on the fired surface of the segment were severe; the maximum depth of concrete spalling on the fired surface of the segment at different fire temperatures was 600°C: 15 mm; 800°C: 45 mm; and 1,000°C: 67 mm; further, the main reinforcement was exposed or even softened. Cracking was also initiated on the unfired surface, and even penetrating cracks developed on the side surface. The damage at both ends of the segment was more severe than that in the center. The fire temperatures were 600°C, 800°C, and 1,000°C, the maximum midspan deflections were 5.27, 7.83, and 11.79 mm, the maximum midspan axial forces were 65.58, 208.41, and 333.63 kN, and the maximum reinforcement stresses were 22.49, 35.08, and 52.63 MPa, respectively. The mechanical parameters of the segment increased during the firing process and recovered during the cooling process, which is equivalent to a loading and unloading cycle for the segment. This study advances the understanding of the structural performance of shield tunnel segments subjected to different fire temperatures.
    • Download: (2.800Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Experimental Research on the Structural Performance of Shield Tunnel Segments Subjected to Different Fire Temperatures

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4304566
    Collections
    • Journal of Materials in Civil Engineering

    Show full item record

    contributor authorHongbin Chen
    contributor authorYujing Jiang
    contributor authorDongdong Pan
    contributor authorHuibin Sun
    contributor authorQian Zhang
    contributor authorPeng Yan
    date accessioned2025-04-20T10:21:51Z
    date available2025-04-20T10:21:51Z
    date copyright9/26/2024 12:00:00 AM
    date issued2024
    identifier otherJMCEE7.MTENG-17685.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4304566
    description abstractIn order to determine the damaging effect of different fire temperatures on a segment, experimental research was carried out on the structural performance of segments subjected to different fire temperatures. A temperature plateau occurred when the temperature reached 100°C. There were two temperature layers across the 300 mm thickness of the segment due to heating on one side only, and the temperature gradient within 0–50 mm was much more significant than that within 50–300 mm. The concrete spalling and the cracking initiated on the fired surface of the segment were severe; the maximum depth of concrete spalling on the fired surface of the segment at different fire temperatures was 600°C: 15 mm; 800°C: 45 mm; and 1,000°C: 67 mm; further, the main reinforcement was exposed or even softened. Cracking was also initiated on the unfired surface, and even penetrating cracks developed on the side surface. The damage at both ends of the segment was more severe than that in the center. The fire temperatures were 600°C, 800°C, and 1,000°C, the maximum midspan deflections were 5.27, 7.83, and 11.79 mm, the maximum midspan axial forces were 65.58, 208.41, and 333.63 kN, and the maximum reinforcement stresses were 22.49, 35.08, and 52.63 MPa, respectively. The mechanical parameters of the segment increased during the firing process and recovered during the cooling process, which is equivalent to a loading and unloading cycle for the segment. This study advances the understanding of the structural performance of shield tunnel segments subjected to different fire temperatures.
    publisherAmerican Society of Civil Engineers
    titleExperimental Research on the Structural Performance of Shield Tunnel Segments Subjected to Different Fire Temperatures
    typeJournal Article
    journal volume36
    journal issue12
    journal titleJournal of Materials in Civil Engineering
    identifier doi10.1061/JMCEE7.MTENG-17685
    journal fristpage04024411-1
    journal lastpage04024411-11
    page11
    treeJournal of Materials in Civil Engineering:;2024:;Volume ( 036 ):;issue: 012
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian