Show simple item record

contributor authorVakili, Samira
contributor authorVivacqua, Thiago
contributor authorGetgood, Alan
contributor authorWilling, Ryan
date accessioned2024-12-24T19:16:02Z
date available2024-12-24T19:16:02Z
date copyright5/13/2024 12:00:00 AM
date issued2024
identifier issn0148-0731
identifier otherbio_146_10_101006.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4303616
description abstractUnderstanding the biomechanical impact of injuries and reconstruction of the anterior cruciate ligament (ACL) is vital for improving surgical treatments that restore normal knee function. The purpose of this study was to develop a technique that enables parametric analysis of the effect of the ACL reconstruction (ACLR) in cadaver knees, by replacing its contributions with that of a specimen-specific virtual ACLR that can be enabled, disabled, or modified. Twelve ACLR reconstructed knees were mounted onto a motion simulator. In situ ACLR graft forces were measured using superposition, and these data were used to design specimen-specific virtual ACLRs that would yield the same ligament force-elongation behaviors. Tests were then repeated using the virtual ACLR in place of the real ACLR and following that in ACL deficient knee by disabling the virtual ACLR. In comparison to the ACL deficient state, the virtual ACLRs were able to restore knee stability to the same extent as real ACLRs. The average differences between the anterior tibial translation (ATT) of the virtual ACLR versus the real ACLR were +1.6 ± 0.9 mm (p = 0.4), +2.1 ± 0.4 mm (p = 0.4), and +1.0 ± 0.9 mm (p = 0.4) during Anterior drawer, Lachman and Pivot-shift tests, respectively, which is small in comparison to the full ATT range of motion (ROM) of these knees. Therefore, we conclude that a virtual ACLR can be used in place of real ACLR during biomechanical testing of cadaveric knees. This capability opens the door for future studies that can leverage parameterization of the ACLR for surgical design optimization.
publisherThe American Society of Mechanical Engineers (ASME)
titleIn Vitro Assessment of Knee Joint Biomechanics Using a Virtual Anterior Cruciate Ligament Reconstruction
typeJournal Paper
journal volume146
journal issue10
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.4065417
journal fristpage101006-1
journal lastpage101006-7
page7
treeJournal of Biomechanical Engineering:;2024:;volume( 146 ):;issue: 010
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record