description abstractWildland firefighters (WLFFs) experience lung function decline due to occupational exposure to fire smoke. WLFFs typically do not wear respiratory personal protective equipment, and if they do, it is a simple bandana, which is not effective at filtering smoke. To pinpoint the biological underpinnings of abnormal respiratory function following 3–7 years of WLFF service, we exposed mice to Douglas fir smoke (DFS) over 8 weeks. Following exposure, we assessed changes in lung structure through Magnetic Resonance Imaging (MRI) and histological analysis, which was supported by immunohistochemistry staining. With MRI, we found that the signal decay time, T2*, from ultrashort echo time (UTE) images was significantly shorter in mice exposed to DFS compared to air controls. In addition, the variation in T2* was more heterogeneously distributed throughout the left lung in DFS-exposed mice, compared to air controls. As confirmed by histological analysis, shorter T2* was caused by larger parenchyma airspace sizes and not fibrotic remodeling. Destruction of the alveolar spaces was likely due to inflammation, as measured by an influx of CD68+ macrophages and destruction due to enhanced neutrophil elastase. In addition, measurements of airspace dimensions from histology were more heterogeneously distributed throughout the lung, corroborating the enhanced relative dispersion of T2*. Findings from this study suggest that the decline in lung function observed in WLFFs may be due to emphysema-like changes in the lung, which can be quantified with MRI.
publisherThe American Society of Mechanical Engineers (ASME)
titleAssessment of Left Lung Remodeling With Magnetic Resonance Imaging in a Murine Model Following Exposure to Douglas Fir Smoke
typeJournal Paper
journal volume146
journal issue7
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.4065272
journal fristpage71010-1
journal lastpage71010-6
page6
treeJournal of Biomechanical Engineering:;2024:;volume( 146 ):;issue: 007
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record