    Collapse Mechanism and Failure Criterion of Superlarge Cooling Tower under Tornado

    Source: Journal of Structural Engineering:;2024:;Volume ( 150 ):;issue: 003::page 04023241-1
    Author:
    Wenjie Li
    ,
    Shitang Ke
    ,
    Xu Chen
    ,
    Lin Zhao
    ,
    Yaojun Ge
    DOI: 10.1061/JSENDH.STENG-12838
    Publisher: ASCE
    Abstract: In this study, the tallest cooling tower (228 m) completed construction in the world in northwest China was chosen to investigate wind-induced failure mechanism of superlarge cooling towers under tornado. A multiscale finite-element model of the structure was established based on the layered shell element method, and a wind tunnel pressure test was carried out using the tornado simulator. Wind pressure distribution characteristics on inner and outer surfaces of the cooling tower under tornado were analyzed. Moreover, characteristics of the whole wind-induced collapse process of the cooling tower under tornado were studied by combining incremental dynamic analytical method, and the collapse mechanism of a superlarge cooling tower under tornado was extracted. Finally, the failure criterion of the structure under tornado based on the variation rate of the torsion angle was proposed. Results demonstrated that wind pressure showed a circumferential even distribution pattern on the surface of the superlarge cooling tower under tornado, and it generally presented negative pressures. When the cooling tower is located at the tornado vortex core, it is the most dangerous and vulnerable to collapse. Under tornado effects, the cooling tower presented bypassing suction and torsional collapse attitudes from inside to outside. The cooling tower element is designed to improve the antitornado bearing capacity by developing a membrane mechanism. The cooling tower collapsed and failed when the torsion angle failure index φ>0.25.
    • Download: (4.773Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Collapse Mechanism and Failure Criterion of Superlarge Cooling Tower under Tornado

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4296821
    Collections
    • Journal of Structural Engineering

    Show full item record

    contributor authorWenjie Li
    contributor authorShitang Ke
    contributor authorXu Chen
    contributor authorLin Zhao
    contributor authorYaojun Ge
    date accessioned2024-04-27T22:30:41Z
    date available2024-04-27T22:30:41Z
    date issued2024/03/01
    identifier other10.1061-JSENDH.STENG-12838.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4296821
    description abstractIn this study, the tallest cooling tower (228 m) completed construction in the world in northwest China was chosen to investigate wind-induced failure mechanism of superlarge cooling towers under tornado. A multiscale finite-element model of the structure was established based on the layered shell element method, and a wind tunnel pressure test was carried out using the tornado simulator. Wind pressure distribution characteristics on inner and outer surfaces of the cooling tower under tornado were analyzed. Moreover, characteristics of the whole wind-induced collapse process of the cooling tower under tornado were studied by combining incremental dynamic analytical method, and the collapse mechanism of a superlarge cooling tower under tornado was extracted. Finally, the failure criterion of the structure under tornado based on the variation rate of the torsion angle was proposed. Results demonstrated that wind pressure showed a circumferential even distribution pattern on the surface of the superlarge cooling tower under tornado, and it generally presented negative pressures. When the cooling tower is located at the tornado vortex core, it is the most dangerous and vulnerable to collapse. Under tornado effects, the cooling tower presented bypassing suction and torsional collapse attitudes from inside to outside. The cooling tower element is designed to improve the antitornado bearing capacity by developing a membrane mechanism. The cooling tower collapsed and failed when the torsion angle failure index φ>0.25.
    publisherASCE
    titleCollapse Mechanism and Failure Criterion of Superlarge Cooling Tower under Tornado
    typeJournal Article
    journal volume150
    journal issue3
    journal titleJournal of Structural Engineering
    identifier doi10.1061/JSENDH.STENG-12838
    journal fristpage04023241-1
    journal lastpage04023241-13
    page13
    treeJournal of Structural Engineering:;2024:;Volume ( 150 ):;issue: 003
    contenttypeFulltext