    Ultimate Shear Capacity of the Cold-Formed Steel Torsionally Restrained Beam-to-Column Moment Connection with a Three-Bolted Clip Angle and Flange Cleat

    Source: Journal of Structural Engineering:;2024:;Volume ( 150 ):;issue: 006::page 04024045-1
    Author:
    Nagaraju Mallepogu
    ,
    Mahendrakumar Madhavan
    DOI: 10.1061/JSENDH.STENG-12724
    Publisher: ASCE
    Abstract: In the current research work, the shear capacity of the cold-formed steel (CFS) three-bolted clip angle (CA) beam-to-column moment connection (3BM) is investigated with 45 laboratory test results. The 3BM connection comprises a three-bolted CA connector that connects the web portions and a bolted flange cleat (FC) that connects the flange portions of the beam and column; in comparison, the three-bolted shear connection (3BS) connects only the web portions of the beam and column. The presence of the FC improved the shear strength of the 3BM connection over the 3BS connection and it is quantified using a coefficient called the “rigidity factor (β).” A shift in the failure mode of CAs from shear local buckling in a 3BS connection to tearing failure in a 3BM connection was observed as the FC resists beam torsional deformation and delays the early local buckling of the CA. The existing design shear equation of the 3BS connection is improved by expressing it as a function of CA failure modes. Following the same trend, the existing design shear method for the CFS moment connection is improved by incorporating the failure modes of the CA boundary conditions along with the geometric and material properties of both the CA and FC for the present 3BM connection. In addition, an empirical shear design equation is suggested for the 3BM connection. The design factors of the proposed 3BM shear equations for load and resistance factor design, limit state design, and allowable strength design methods were evaluated from the reliability study.
    • Download: (5.837Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Ultimate Shear Capacity of the Cold-Formed Steel Torsionally Restrained Beam-to-Column Moment Connection with a Three-Bolted Clip Angle and Flange Cleat

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4296809
    Collections
    • Journal of Structural Engineering

    Show full item record

    contributor authorNagaraju Mallepogu
    contributor authorMahendrakumar Madhavan
    date accessioned2024-04-27T22:30:18Z
    date available2024-04-27T22:30:18Z
    date issued2024/06/01
    identifier other10.1061-JSENDH.STENG-12724.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4296809
    description abstractIn the current research work, the shear capacity of the cold-formed steel (CFS) three-bolted clip angle (CA) beam-to-column moment connection (3BM) is investigated with 45 laboratory test results. The 3BM connection comprises a three-bolted CA connector that connects the web portions and a bolted flange cleat (FC) that connects the flange portions of the beam and column; in comparison, the three-bolted shear connection (3BS) connects only the web portions of the beam and column. The presence of the FC improved the shear strength of the 3BM connection over the 3BS connection and it is quantified using a coefficient called the “rigidity factor (β).” A shift in the failure mode of CAs from shear local buckling in a 3BS connection to tearing failure in a 3BM connection was observed as the FC resists beam torsional deformation and delays the early local buckling of the CA. The existing design shear equation of the 3BS connection is improved by expressing it as a function of CA failure modes. Following the same trend, the existing design shear method for the CFS moment connection is improved by incorporating the failure modes of the CA boundary conditions along with the geometric and material properties of both the CA and FC for the present 3BM connection. In addition, an empirical shear design equation is suggested for the 3BM connection. The design factors of the proposed 3BM shear equations for load and resistance factor design, limit state design, and allowable strength design methods were evaluated from the reliability study.
    publisherASCE
    titleUltimate Shear Capacity of the Cold-Formed Steel Torsionally Restrained Beam-to-Column Moment Connection with a Three-Bolted Clip Angle and Flange Cleat
    typeJournal Article
    journal volume150
    journal issue6
    journal titleJournal of Structural Engineering
    identifier doi10.1061/JSENDH.STENG-12724
    journal fristpage04024045-1
    journal lastpage04024045-23
    page23
    treeJournal of Structural Engineering:;2024:;Volume ( 150 ):;issue: 006
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian