YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASCE
    • Journal of Structural Engineering
    • View Item
    •   YE&T Library
    • ASCE
    • Journal of Structural Engineering
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Experimental Parameter Study on CLT Shear Walls with Self-Tapping Screw Connections

    Source: Journal of Structural Engineering:;2024:;Volume ( 150 ):;issue: 001::page 04023192-1
    Author:
    Yuxin Pan
    ,
    Thomas Teflissi
    ,
    Thomas Tannert
    DOI: 10.1061/JSENDH.STENG-12710
    Publisher: ASCE
    Abstract: This paper presents experimental investigations on the lateral performance of cross-laminated timber (CLT) shear walls with customized self-tapping screw (STS) connections. The panel-to-base (hold-downs and shear brackets) and panel-to-panel (spline) connections were tested under quasi-static monotonic and reversed cyclic loading to derive design values of STS, which were shown to be 2.8–3.6 times higher than those calculated using the current Canadian timber design standard. Then, a total of 26 CLT shear walls, including single-, double- and triple-panel configurations, were tested, again under quasi-static monotonic and reversed cyclic loading. The shear walls consisted of five-ply, 139-mm-thick and 3-m-high CLT panels with aspect ratio of either 2∶1 or 3∶1, and different numbers of STS in the connections. The shear wall strength and corresponding displacements increased with the number of screws in hold-downs and spline joints; further, it increased with number of connected panels and decreased as a function of aspect ratio. The data can be used for developing and calibrating numerical models to investigate the lateral responses of CLT shear walls with different configurations.
    • Download: (4.087Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Experimental Parameter Study on CLT Shear Walls with Self-Tapping Screw Connections

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4296807
    Collections
    • Journal of Structural Engineering

    Show full item record

    contributor authorYuxin Pan
    contributor authorThomas Teflissi
    contributor authorThomas Tannert
    date accessioned2024-04-27T22:30:14Z
    date available2024-04-27T22:30:14Z
    date issued2024/01/01
    identifier other10.1061-JSENDH.STENG-12710.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4296807
    description abstractThis paper presents experimental investigations on the lateral performance of cross-laminated timber (CLT) shear walls with customized self-tapping screw (STS) connections. The panel-to-base (hold-downs and shear brackets) and panel-to-panel (spline) connections were tested under quasi-static monotonic and reversed cyclic loading to derive design values of STS, which were shown to be 2.8–3.6 times higher than those calculated using the current Canadian timber design standard. Then, a total of 26 CLT shear walls, including single-, double- and triple-panel configurations, were tested, again under quasi-static monotonic and reversed cyclic loading. The shear walls consisted of five-ply, 139-mm-thick and 3-m-high CLT panels with aspect ratio of either 2∶1 or 3∶1, and different numbers of STS in the connections. The shear wall strength and corresponding displacements increased with the number of screws in hold-downs and spline joints; further, it increased with number of connected panels and decreased as a function of aspect ratio. The data can be used for developing and calibrating numerical models to investigate the lateral responses of CLT shear walls with different configurations.
    publisherASCE
    titleExperimental Parameter Study on CLT Shear Walls with Self-Tapping Screw Connections
    typeJournal Article
    journal volume150
    journal issue1
    journal titleJournal of Structural Engineering
    identifier doi10.1061/JSENDH.STENG-12710
    journal fristpage04023192-1
    journal lastpage04023192-13
    page13
    treeJournal of Structural Engineering:;2024:;Volume ( 150 ):;issue: 001
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian